基于可变形配准的电影MRI分析量化心肌形变:与标记CMR的验证对比
本研究以谐波相位(HARP)标记心血管磁共振为标准参考,验证可变形配准算法(DRA)在电影平衡稳态自由进动(bSSFP)序列上评估整体纵向应变(GLS)和整体环向应变(GCS)的效能;17例患者和17名志愿者结果显示,DRA与HARP的GLS和GCS均呈强相关,且DRA的观察者内和观察者间变异系数持续更低,提示基于电影bSSFP的DRA可提供可靠的收缩期峰值GCS和GLS测量,重复性优于HARP。
要点
- DRA与HARP在GLS和GCS测量上均呈强相关,支持电影bSSFP用于心肌应变分析。
- DRA的观察者内和观察者间变异系数持续低于HARP,重复性更优。
- DRA和HARP应变数据均与左心室射血分数(LVEF)呈显著相关。
核心结论
- 基于非刚性形变方法的DRA可基于电影bSSFP提供可靠的收缩期峰值GCS和GLS测量,且观察者内和观察者间重复性优于HARP。
研究设计与样本
- 验证性研究,纳入17例患者和17名志愿者,均接受短轴堆栈及2/4腔室电影bSSFP成像,并匹配长轴切片和心室中部空间调制磁化(SPAMM)心肌标记;以HARP标记心血管磁共振为标准参考,对bSSFP数据应用逆向DRA评估GLS和GCS;采用标准半自动短轴堆栈分割分析左心室容积和射血分数;观察者内和观察者间变异性分别基于同一观察者重复分析和第二观察者分析评估。
诊断标准与关键数值
- DRA与HARP心肌GLS比较:R²=0.75,p<0.0001。
- DRA与HARP心内膜GLS比较:R²=0.61,p<0.0001。
- DRA与HARP心肌GCS比较:R²=0.61,p<0.0001。
- DRA与HARP心内膜GCS比较:R²=0.51,p<0.0001。
- 患者组整体LVEF为53.7%(IQR 43.9/64.0%),健康志愿者组为62.6%(IQR 61.1/66.2%),患者组显著低于志愿者组(p=0.0099)。
临床应用与阅片要点
- 基于电影bSSFP的DRA可用于评估收缩期峰值GLS和GCS,且重复性优于HARP标记CMR。
- DRA和HARP应变数据均与整体左心室功能(LVEF)呈显著相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To validate deformable registration algorithms (DRAs) for cine balanced steady-state free precession (bSSFP) assessment of global longitudinal strain (GLS) and global circumferential strain (GCS) using harmonic phase (HARP) cardiovascular magnetic resonance as standard of reference (SoR).
METHODS: Seventeen patients and 17 volunteers underwent short axis stack and 2-/4-chamber cine bSSFP imaging with matching slice long-axis and mid-ventricular spatial modulation of magnetization (SPAMM) myocardial tagging. Inverse DRA was applied on bSSFP data for assessment of GLS and GCS while myocardial tagging was processed using HARP. Intra- and inter-observer variability assessment was based on repeated analysis by a single observer and analysis by a second observer, respectively. Standard semi-automated short axis stack segmentation was performed for analysis of left ventricular (LV) volumes and ejection fraction (EF).
RESULTS: DRA demonstrated strong relationships to HARP for myocardial GLS (R2 = 0.75; p < 0.0001) and endocardial GLS (R2 = 0.61; p < 0.0001). GCS result comparison also demonstrated significant relationships between DRA and HARP for myocardial strain (R2 = 0.61; p < 0.0001) and endocardial strain (R2 = 0.51; p < 0.0001). Both methods demonstrated small systematic errors for intra- and inter-observer variability but DRA demonstrated consistently lower CV. Global LVEF was significantly lower (p = 0.0099) in patients (53.7%; IQR 43.9/64.0%) than in healthy volunteers (62.6%; IQR 61.1/66.2%). DRA and HARP strain data demonstrated significant relationships to LVEF.
CONCLUSIONS: Non-rigid deformation method-based DRA provides a reliable measure of peak systolic GCS and GLS based on cine bSSFP with superior intra- and inter-observer reproducibility compared to HARP.
KEY POINT: • Myocardial strain can be reliably analyzed using inverse deformable registration algorithms (DRAs) on cine CMR. • Inverse DRA-derived strain shows higher reproducibility than tagged CMR. • DRA and tagged CMR-based myocardial strain demonstrate strong relationships to global left ventricular function.
引用
- Lamacie MM, Houbois CP, Greiser A, et al. Quantification of myocardial deformation by deformable registration-based analysis of cine MRI: validation with tagged CMR. Eur Radiol. 2019. PMID: 30770973. doi:10.1007/s00330-019-06019-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。