机构体模特异性诊断参考水平在CT血管造影中的实施
该回顾性研究纳入2016年1月至2017年1月间1344例CTA检查(主动脉733例、肺动脉406例、盆腔/下肢205例),基于水当量直径(Dw)建立机构体模特异性诊断参考水平(DRL),并与德国和英国的国家体模非特异性DRL比较。结果显示所有CTA方案的CTDIvol随Dw增加呈线性上升(R²=0.93–0.95),机构DRL在平均体型患者中低于国家DRL,且体模特异性DRL在体型较小患者中检出更多剂量异常值(56.4% vs 16.2%)。
要点
- 机构体模特异性DRL以Dw对应CTDIvol第75百分位为上限,较国家体模非特异性DRL更精确。
- CTDIvol随Dw增加呈线性上升,主动脉、肺动脉、盆腔/下肢CTA的R²分别为0.95、0.94、0.93。
- 体型较小患者中,体模特异性DRL检出剂量异常值比例高于国家体模非特异性DRL(56.4% vs 16.2%)。
核心结论
- 实施机构体模特异性DRL用于CTA检查,相比国家体模非特异性DRL可实现更精确的分析。
研究设计与样本
- 回顾性研究,纳入2016年1月至2017年1月间1344例CTA检查(主动脉733例、肺动脉406例、盆腔/下肢205例),自动计算每例患者的水当量直径(Dw),分析Dw与CTDIvol关系并以第75百分位作为机构DRL上限,与德国和英国的国家体模非特异性DRL比较。
诊断标准与关键数值
- 机构DRL以Dw对应CTDIvol的第75百分位为上限;平均体型患者机构DRL:主动脉CTA(Dw 28.2 cm)CTDIvol 7.6 mGy,肺动脉CTA(Dw 27.9 cm)CTDIvol 11.8 mGy,盆腔/下肢CTA(Dw 20.0 cm)CTDIvol 6.4 mGy,均低于国家DRL。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To generate institutional size-specific diagnostic reference levels (DRLs) for computed tomography angiography (CTA) examinations and assess the potential for dose optimization compared to size-independent DRLs.
MATERIALS AND METHODS: CTA examinations of the aorta, the pulmonary arteries and of the pelvis/lower extremity performed between January 2016 and January 2017 were included in our retrospective study. Water equivalent diameter (Dw) was automatically calculated for each patient. The relationship between Dw and computed tomography dose index (CTDIvol) was analyzed and the 75th percentile was chosen as the upper limit for institutional DRLs. Size-specific institutional DRLs were compared to national size-independent DRLs from Germany and the UK.
RESULTS: A total of 1344 examinations were included in our study (n = 733 aortic CTA, n = 406 pulmonary CTA, n = 205 pelvic/lower extremity CTA). Mean Dw was 26 ± 9 cm and mean CTDIvol was 7.0 ± 4.6 mGy. For all CTA protocols, there was a linear progression of CTDIvol with increasing Dw with an R² = 0.95 in aortic CTA, R² = 0.94 in pulmonary CTA and R² = 0.93 in pelvic/lower extremity CTA. Median CTDIvol increased by 0.57 mGy per additional cm Dw in aortic CTA, by 1.1 mGy in pulmonary CTA and by 0.31 mGy in pelvic/lower extremity CTA. Institutional DRLs were lower than national DRLs for average size patients (aortic CTA: Dw 28.2 cm, CTDIvol 7.6 mGy; pulmonary CTA, Dw 27.9 cm, CTDIvol 11.8 mGy; pelvic/lower extremity CTA, Dw 20.0 cm, CTDIvol 6.4 mGy). More dose outliers in small patients were detected with size-specific DRLs compared to national size-independent DRLs (56.4% vs 16.2%).
CONCLUSION: We implemented institutional size-specific DRLs for CTA examinations which enabled a more precise analysis compared to national sizeindependent DRLs.
引用
- Klosterkemper Y, Thomas C, Bethge OT, et al. Implementation of Institutional Size-Specific Diagnostic Reference Levels for CT Angiography. Acad Radiol. 2019. PMID: 30803896. doi:10.1016/j.acra.2019.01.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。