热加速凝胶对猪肺微波消融区体积的影响:一项猪研究
在9只12周龄雄性家猪中行32次透视引导下微波肺消融,比较经皮或支气管内注射热加速凝胶与对照的消融区体积;热加速凝胶组消融区体积大于对照组,经皮注射组大于支气管内注射组,而支气管内注射组消融区大小分布更均匀。
要点
- 热加速凝胶可使正常猪肺微波消融区体积增大(4.3 cm³ vs 2.1 cm³,P < .001)。
- 经皮注射凝胶的消融区体积大于支气管内注射(4.8 cm³ vs 3.3 cm³,P = .03)。
- 支气管内注射凝胶后消融区大小分布更均匀(标准误 0.07 vs 0.13,P = .03)。
核心结论
- 在正常猪肺组织中,使用热加速凝胶可获得更大的微波消融区体积;经皮注射热加速凝胶比支气管内注射产生更大的消融区体积,而支气管内途径观察到更均匀和精确的消融区大小。
研究设计与样本
- 动物实验:9只12周龄雄性家猪在全身麻醉下经透视引导行32次连续微波肺消融(2017年9月至2018年4月);实验组为经皮注射热加速凝胶(n = 16)或经可弯曲支气管镜支气管内注射(n = 8),对照组不用凝胶(n = 8);动物处死后取肺组织,以氯化三苯基四氮唑活力染色计算消融区体积为主要结局,用广义混合模型分析。
关键影像表现/征象
- 热加速凝胶消融区体积大于对照消融(4.3 cm³[95%CI:3.4,5.5] vs 2.1 cm³[95%CI:1.4,2.9],P < .001)。
- 热加速凝胶消融中,经皮注射后消融区平均体积大于支气管内注射(4.8 cm³[95%CI:3.6,6.4] vs 3.3 cm³[95%CI:2.9,3.8],P = .03)。
- 支气管内注射凝胶后消融区大小分布更均匀(标准误,经皮 vs 支气管内:0.13 vs 0.07,P = .03)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Thermal ablation of cancers may be associated with high rates of local tumor progression. A thermal accelerant gel has been developed to improve the transmission of microwave energy in biologic tissues with the aim of enlarging the thermal ablation zone. Purpose To determine the effects of a thermal accelerant gel on microwave ablation zone volumes in porcine lung and to compare percutaneous and endobronchial delivery methods. Materials and Methods Thirty-two consecutive microwave lung ablations were performed in nine 12-week-old domestic male swine under general anesthesia by using fluoroscopic guidance between September 2017 and April 2018. Experimental ablations were performed following percutaneous injection of thermal accelerant into the lung (n = 16) or after endobronchial injection by using a flexible bronchoscope (n = 8). Control ablations were performed without accelerant gel (n = 8). Lung tissue was explanted after the animals were killed, and ablation zone volumes were calculated as the primary outcome measure by using triphenyltetrazolium chloride vital staining. Differences in treatment volumes were analyzed by generalized mixed modeling. Results Thermal accelerant ablation zone volumes were larger than control ablations (accelerant vs control ablation, 4.3 cm3 [95% confidence interval: 3.4, 5.5] vs 2.1 cm3 [95% confidence interval: 1.4, 2.9], respectively; P < .001). Among ablations with the thermal accelerant, those performed following percutaneous injection had a larger average ablation zone volume than those performed following endobronchial injection (percutaneous vs endobronchial, 4.8 cm3 [95% confidence interval: 3.6, 6.4] vs 3.3 cm3 [95% confidence interval: 2.9, 3.8], respectively; P = .03). Ablation zones created after endobronchial gel injection were more uniform in size distribution (standard error, percutaneous vs endobronchial: 0.13 vs 0.07, respectively; P = .03). Conclusion Use of thermal accelerant results in larger microwave ablation zone volumes in normal porcine lung tissue. Percutaneous thermal accelerant injection leads to a larger ablation zone volume compared with endobronchial injection, whereas a more homogeneous and precise ablation zone size is observed by using the endobronchial approach. © RSNA, 2019 See also the editorial by Goldberg in this issue.
引用
- Maxwell AWP, Park WKC, Baird GL, et al. Effects of a Thermal Accelerant Gel on Microwave Ablation Zone Volumes in Lung: A Porcine Study. Radiology. 2019. PMID: 30747590. doi:10.1148/radiol.2019181652
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。