重度COPD患者用力呼吸时膈肌运动幅度减小且速度减慢:平板探测器动态胸片的时间分辨定量分析
本研究纳入31例COPD患者与31例按年龄、性别、身高、体重匹配的正常对照,用平板探测器动态胸片在用力呼吸时时间分辨定量测量膈肌运动幅度与峰值运动速度。GOLD 3/4组双侧膈肌运动幅度显著低于正常组和GOLD 1/2组;左侧膈肌吸气相峰值速度在GOLD 1/2组低于正常组。
要点
- 用力呼吸动态胸片可定量测量膈肌运动幅度与峰值运动速度。
- GOLD 3/4组双侧膈肌运动幅度显著低于正常组与GOLD 1/2组。
- 膈肌运动幅度与VC、%VC及FEV1相关,峰值速度与肺功能无显著相关。
核心结论
- 动态胸片时间分辨定量分析显示,COPD患者与正常人在用力呼吸时的膈肌运动存在差异,GOLD 3/4组膈肌运动幅度显著低于GOLD 1/2组和正常组。
研究设计与样本
- 研究纳入31例COPD患者和31例按年龄、性别、身高、体重匹配的正常对照,均使用平板探测器系统行用力呼吸时动态胸片检查。
关键影像表现/征象
- GOLD 3/4组右侧膈肌运动幅度为39.8 ± 15.3 mm,正常组为52.7 ± 15.1 mm(P = 0.030)。
- GOLD 3/4组左侧膈肌运动幅度为43.7 ± 14.0 mm,正常组为56.9 ± 15.5 mm(P = 0.017)。
- GOLD 3/4组右侧膈肌运动幅度为39.8 ± 15.3 mm,GOLD 1/2组为54.4 ± 16.7 mm(P = 0.036)。
- GOLD 3/4组左侧膈肌运动幅度为43.7 ± 14.0 mm,GOLD 1/2组为60.5 ± 13.9 mm(P = 0.008)。
诊断标准与关键数值
- COPD按GOLD标准分类:GOLD 1组3例、GOLD 2组12例、GOLD 3组13例、GOLD 4组3例。
- 左侧膈肌吸气相峰值运动速度:GOLD 1/2组24.5 ± 8.0 mm/s vs 正常组33.6 ± 14.0 mm/s(P = 0.038)。
- 左侧膈肌吸气相峰值运动速度:GOLD 3/4组25.6 ± 6.8 mm/s vs 正常组33.6 ± 14.0 mm/s(P = 0.067)。
- 膈肌运动幅度与VC、%VC及FEV1相关,峰值运动速度与肺功能检查无显著相关。
临床应用与阅片要点
- 用力呼吸动态胸片的时间分辨定量分析可提供膈肌运动幅度和峰值运动速度数据。
- 阅片时可关注GOLD 3/4组患者双侧膈肌运动幅度较正常组和GOLD 1/2组减低的表现。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the diaphragmatic motion in chronic obstructive pulmonary disease (COPD) patients during forced breathing by time-resolved quantitative analysis using dynamic chest radiography and to demonstrate the characteristics and the difference from that in normal subjects.
MATERIALS AND METHODS: Thirty-one COPD patients and a matched control of 31 normal subjects on age, sex, height, and weight, who underwent chest radiographs during forced breathing using dynamic chest radiography, were included in this study. COPD patients were classified based on the criteria of the Global Initiative for Chronic Obstructive Lung Disease (GOLD) (GOLD 1, n = 3; GOLD 2, n = 12; GOLD 3, n = 13; GOLD 4, n = 3). We measured excursions and peak motion speeds of the diaphragms for each participant. We compared the results among GOLD 1/2, GOLD 3/4 groups and normal subjects and investigated associations between the data, and participants' demographics, or pulmonary function.
RESULTS: The excursions of bilateral diaphragms were significantly decreased in the GOLD 3/4 group relative to normal subjects (right, 39.8 ± 15.3 mm vs. 52.7 ± 15.1 mm, P = 0.030; left, 43.7 ± 14.0 mm vs. 56.9 ± 15.5 mm, P = 0.017; mean ± standard deviation) and the GOLD 1/2 group (right, 39.8 ± 15.3 mm vs. 54.4 ± 16.7 mm, P = 0.036; left, 43.7 ± 14.0 mm vs. 60.5 ± 13.9 mm, P = 0.008). The peak motion speeds of the left diaphragm in the inspiratory phase were slower in the GOLD 1/2 group than in normal subjects (24.5 ± 8.0 mm/s vs. 33.6 ± 14.0 mm/s, P = 0.038), and in the GOLD 3/4 group than in normal subjects (25.6 ± 6.8 mm/s vs. 33.6 ± 14.0 mm/s, P = 0.067). The excursions of the diaphragms showed correlation with VC, %VC, and FEV1, while the peak motion speeds showed no significant correlation with pulmonary function tests.
CONCLUSIONS: Time-resolved quantitative analysis of diaphragms with dynamic chest radiography indicated differences in diaphragmatic motion between COPD groups and normal subjects during forced breathing. The excursions of the diaphragms during forced breathing were significantly lower in the GOLD 3/4 group than those in the GOLD 1/2 group and normal subjects.
引用
- Hida T, Yamada Y, Ueyama M, et al. Decreased and slower diaphragmatic motion during forced breathing in severe COPD patients: Time-resolved quantitative analysis using dynamic chest radiography with a flat panel detector system. Eur J Radiol. 2019. PMID: 30777216. doi:10.1016/j.ejrad.2018.12.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。