文献速递胸部CT

锡滤过光谱整形联合第三代迭代重建低剂量CT评估结缔组织病相关间质性肺病的可行性:个体内比较研究

Feasibility of low-dose CT with spectral shaping and third-generation iterative reconstruction in evaluating interstitial lung diseases associated with connective tissue disease: an intra-individual comparison study.
PubMed 文献 · Eur Radiol · 2019-02-08

53例结缔组织病相关间质性肺病患者行常规剂量CT(110 kVp,FBP和ADMIRE重建)及锡滤过低剂量CT(100 kVp,ADMIRE重建),低剂量CT平均辐射剂量降至常规剂量的20%;ADMIRE算法显著改善图像质量,低剂量CT在周围支气管、血管及网状影显示上劣于常规剂量FBP,其余结构相似。

要点

  • 低剂量CT(锡滤过100 kVp联合ADMIRE)平均辐射剂量为常规剂量CT的20%。
  • 常规剂量ADMIRE在主观噪声、条纹伪影、整体图像质量及异常肺结构评分上均优于常规剂量FBP和低剂量ADMIRE。
  • 低剂量ADMIRE在显示周围支气管、血管及网状影上劣于常规剂量FBP,其余正常与异常结构相似。

核心结论

  • 锡滤过联合第三代迭代重建的低剂量CT适用于评估结缔组织病相关间质性肺病的间质性肺病病变;应用ADMIRE算法后CT图像质量显著改善。

研究设计与样本

  • 个体内比较研究,连续纳入53例成人结缔组织病相关间质性肺病患者,先行常规剂量胸部CT(110 kVp,分别以FBP和ADMIRE重建),再行锡滤过低剂量CT(100 kVp,以ADMIRE重建)。

关键影像表现/征象

  • 常规剂量ADMIRE、低剂量ADMIRE、常规剂量FBP的客观图像噪声依次升高(38.08 ± 6.37 HU、51.68 ± 9.06 HU、62.09 ± 10.95 HU),任意两组间p < 0.001。
  • 常规剂量ADMIRE在主观图像噪声、条纹伪影及整体图像质量上显著优于常规剂量FBP和低剂量ADMIRE(均p < 0.001),而后两组间无显著差异。
  • 常规剂量ADMIRE对所有异常肺结构的评分均优于常规剂量FBP(均p < 0.001)。
  • 低剂量ADMIRE在显示周围支气管、血管及网状影上劣于常规剂量FBP(均p < 0.001),其余正常和异常结构在两组间相似。

临床应用与阅片要点

  • 锡滤过光谱整形联合第三代迭代重建可在评估结缔组织病相关间质性肺病时降低辐射剂量至常规剂量的20%。
  • ADMIRE算法可改善低剂量CT对间质性肺病模式的显示,但低剂量ADMIRE在周围支气管、血管及网状影显示上仍劣于常规剂量FBP。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the feasibility of low-dose CT (LDCT) with tin filtration and third-generation iterative reconstruction (IR) in evaluating interstitial lung diseases associated with connective tissue disease (CTD-ILD).

METHODS: Fifty-three consecutive adult patients with CTD-ILD underwent regular-dose chest CT (RDCT) at 110 kVp followed by LDCT with tin-filtered 100 kVp. RDCT was reconstructed with filtered back projection (FBP) and advanced modeled iterative reconstruction (ADMIRE); LDCT was reconstructed with ADMIRE. Image noise, streak artifact, image quality, and visualization of normal and abnormal CT features were evaluated and compared among RDCT-ADMIRE, RDCT-FBP, and LDCT-ADMIRE groups.

RESULTS: The mean radiation dose of LDCT was reduced to 20% of RDCT. Objective image noise of RDCT-ADMIRE (38.08 ± 6.37 HU), LDCT-ADMIRE (51.68 ± 9.06 HU), and RDCT-FBP (62.09 ± 10.95 HU) increased progressively (p < 0.001 in any two pairs). RDCT-ADMIRE significantly improved subjective image noise, streak artifact, and overall image quality compared with RDCT-FBP and LDCT-ADMIRE (all p < 0.001), while no significant difference was noted between the latter two groups. All abnormal lung structures were better scored in RDCT-ADMIRE compared with those in RDCT-FBP (all p < 0.001). LDCT-ADMIRE was inferior to RDCT-FBP in visualizing peripheral bronchi and vessels as well as reticulation (all p < 0.001); other normal and abnormal structures were similar between the two groups.

CONCLUSION: LDCT with tin filtration and third-generation IR was applicable in evaluating ILD lesions of CTD. Image quality was significantly improved after applying ADMIRE algorithm to CT protocols.

KEY POINTS: • Optimization of CT radiation dose is a clinical concern in patients with connective tissue disease. • Spectral shaping and third-generation iterative reconstruction emerge as promising techniques in reducing radiation dose and acquiring desired image quality of CTD-ILD patients. • The third-generation iterative reconstruction algorithm can optimize visualization of ILD patterns in low-dose CT.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Xu X, Sui X, Song L, et al. Feasibility of low-dose CT with spectral shaping and third-generation iterative reconstruction in evaluating interstitial lung diseases associated with connective tissue disease: an intra-individual comparison study. Eur Radiol. 2019. PMID: 30737567. doi:10.1007/s00330-018-5969-y