基于纤维束空间统计的慢性阻塞性肺疾病脑白质轴向扩散率降低及各向异性模式与T2信号增高
本研究纳入13例非低氧血症慢性阻塞性肺疾病(COPD)男性患者与13例年龄性别匹配健康对照,采用纤维束空间统计(TBSS)比较扩散张量成像(DTI)参数。COPD患者轴向扩散率(AD)降低、各向异性模式(MO)及原始T2信号(S0)增高,而部分各向异性(FA)、径向扩散率(RD)和平均扩散率(MD)无差异。作者认为AD降低和MO增高可能反映COPD患者白质完整性的早期改变。
要点
- COPD患者白质AD降低见于颞干、皮质脊髓束、丘脑、下托、大脑脚和中脑。
- COPD患者MO增高见于胼胝体、皮质脊髓束、内囊、小脑脚和内侧丘系。
- COPD患者S0增高见于颞干、小脑脚、脑桥和小脑扁桃体,FA、RD和MD无差异。
核心结论
- 与非低氧血症COPD患者相比,COPD患者AD降低、MO增高,而FA、RD和MD无差异;AD降低和MO增高可能反映COPD患者白质完整性的早期改变。
研究设计与样本
- 研究论文;纳入13例男性非低氧血症COPD患者和13例年龄、性别匹配的健康对照;DTI原始图像经自动化纤维束空间统计(TBSS)流程处理;比较FA、AD、RD、MD、MO和原始T2信号(S0)。
关键影像表现/征象
- COPD患者AD降低见于颞干、皮质脊髓束、丘脑、下托、大脑脚和中脑。
- COPD患者MO增高见于胼胝体、皮质脊髓束、内囊、小脑脚和内侧丘系。
- COPD患者S0增高见于颞干、小脑脚、脑桥和小脑扁桃体。
- COPD患者FA、RD和MD与对照相比无差异。
诊断标准与关键数值
- 统计采用无阈值簇增强,族错误率p < 0.05。
- COPD患者AD降低、MO增高、S0增高均以族错误率p < 0.05为阈值。
- FA、RD和MD在COPD患者与对照间无差异。
临床应用与阅片要点
- 阅片时可关注COPD患者白质AD降低和MO增高的区域分布,但原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Chronic obstructive pulmonary disease (COPD) is considered to be a multi-systemic disease involving pathological changes in the brain. This study investigated how diffusion tensor imaging (DTI) parameters in patients with non-hypoxemic COPD differ from those in controls. Moreover, we tried to examine whether the mode of anisotropy (MO) reflects early changes in white matter (WM) integrity in COPD.
METHODS: DT images were obtained from 13 male COPD patients and 13 age- and sex-matched healthy controls. Raw DT images were processed using an automated tract-based spatial statistics (TBSS) pipeline. DTI scalars of fractional anisotropy (FA); axial, radial, and mean diffusivities (AD, RD, and MD, respectively); MO; and raw T2 signal (S0) were statistically compared between COPD patients and controls. TBSS methods were used for analysis.
RESULTS: In patients with COPD, decreased AD was observed in the temporal stem (TS), corticospinal tract (CST), thalamus, subiculum, crus cerebri, and midbrain. Increased MO values were found in the corpus callosum, CST, internal capsule, cerebellar peduncle (CP), and medial lemniscus (ML). Additionally, increased S0 was found in the TS, CP, pons, and cerebellar tonsil (threshold-free cluster enhancement to a family-wise error rate of p < 0.05).
CONCLUSION: The results revealed decreased AD and increased MO scalars in COPD patients compared with the controls, although there were no differences in FA, RD, and MD scalars. Decreased AD and increased MO scalars may reflect early changes in WM integrity in COPD patients.
引用
- Lee S, Pyun SB, Tae WS, et al. Reduced axial diffusivity and increased mode and T2 signals in cerebral white matter of chronic obstructive pulmonary disease using tract-based spatial statistics. Neuroradiology. 2019. PMID: 30712138. doi:10.1007/s00234-019-02178-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。