文献速递神经CT

比较CT血管造影侧支循环预测急性缺血性卒中患者目标灌注匹配与临床结局

Comparison of CT angiography collaterals for predicting target perfusion profile and clinical outcome in patients with acute ischemic stroke.
PubMed 文献 · Eur Radiol · 2019-02-14

本研究纳入73例发病5至15小时或发病时间不明的急性缺血性卒中患者,比较单期与多期CT血管造影对侧支循环的评估能力及其预测CT灌注目标匹配和90天改良Rankin量表评分0-2的能力。多期CT血管造影对侧支循环的评估优于单期,且预测目标匹配和临床结局的能力更佳。多期CT血管造影侧支循环评分>3分最能识别CT灌注目标匹配并预测90天改良Rankin量表评分0-2。

要点

  • 多期CT血管造影评估侧支循环优于单期,单期会低估侧支循环状态。
  • 多期CT血管造影侧支评分>3分预测CT灌注目标匹配敏感度78.4%、特异度90.9%。
  • 多期CT血管造影侧支评分>3分预测90天改良Rankin量表评分0-2敏感度84.8%、特异度69.4%。

核心结论

  • 多期CT血管造影对侧支循环的评估优于单期CT血管造影,多期CT血管造影侧支评分>3分优化了对CT灌注目标匹配和良好临床结局的预测。

研究设计与样本

  • 研究纳入73例急性缺血性卒中患者,发病时间在5至15小时或发病时间不明,伴大脑中动脉M1/M2段和/或颅内颈内动脉闭塞,均接受头部平扫CT和CT灌注检查。

关键影像表现/征象

  • 与多期CT血管造影相比,单期CT血管造影低估了侧支循环状态(p<0.01)。
  • 更好的侧支循环与更小的缺血核心体积和更大的CT灌注错配比相关。

诊断标准与关键数值

  • CT灌注目标匹配定义为缺血核心<70 ml、错配比≥1.8且绝对差值≥15 ml。
  • 多期CT血管造影预测目标匹配的AUC=0.902(95%CI 0.809, 0.959),优于单期CT血管造影(p<0.05)。
  • 多期CT血管造影预测90天改良Rankin量表评分0-2的AUC=0.771(95%CI 0.655, 0.864),优于单期CT血管造影(p<0.05)。
  • 多期CT血管造影侧支评分>3分识别目标匹配的敏感度78.4%、特异度90.9%。
  • 多期CT血管造影侧支评分>3分预测90天改良Rankin量表评分0-2的敏感度84.8%、特异度69.4%。

临床应用与阅片要点

  • 多期CT血管造影较单期CT血管造影能更好地评估侧支循环,单期CT血管造影可能低估侧支循环状态。
  • 多期CT血管造影侧支评分>3分有助于识别CT灌注目标匹配的患者并预测90天改良Rankin量表评分0-2。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare collateral status on single-phase CT angiography (sCTA) and multiphase CT angiography (mCTA) and their ability to predict a target mismatch on CT perfusion (CTP) and clinical outcome in patients with acute ischemic stroke (AIS).

METHODS: Seventy-three AIS patients with stroke onset between 5 and 15 h or with unclear onset time and occlusions in the M1/M2 segment of the middle cerebral artery and/or intracranial internal carotid artery underwent head non-contrast CT and CTP. Simulated sCTA and mCTA were reconstructed from CTP data and were compared for collaterals assessment. The ability to predict target mismatch on CTP (an ischemic core < 70 ml, a mismatch ratio ≥ 1.8, and an absolute difference ≥ 15 ml) and 90-day modified Rankin Scale (mRS) score of 0-2 was compared between sCTA and mCTA by using receiver operating curve analysis.

RESULTS: sCTA underestimated the collateral status when compared with mCTA (p < 0.01). The ability of mCTA to predict target mismatch (AUC = 0.902, 95% confidence interval [CI] 0.809, 0.959) and clinical outcome (AUC = 0.771; 95% CI, 0.655, 0.864) was better than that of sCTA (p < 0.05 overall). A mCTA collateral score of > 3 best identified the target mismatch (sensitivity, 78.4%; specificity, 90.9%) and predicted 90-day mRS score of 0-2 (sensitivity, 84.8%; specificity, 69.4%).

CONCLUSIONS: The collaterals were better estimated by mCTA compared with sCTA. A mCTA collateral score of > 3 optimized the prediction of a target mismatch on CTP and a good clinical outcome in patients with AIS.

KEY POINTS: • Collateral circulation is a key determinant of ischemic core and penumbra. Better collaterals are associated with smaller ischemic core volumes and larger mismatch ratios on CT perfusion. • The collaterals can be better estimated by multiphase CTA compared with single-phase CTA. • A collateral score of > 3 on multiphase CTA best identifies patients with target mismatch on CT perfusion and predicts 90-day mRS score of 0-2.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Lu SS, Zhang X, Xu XQ, et al. Comparison of CT angiography collaterals for predicting target perfusion profile and clinical outcome in patients with acute ischemic stroke. Eur Radiol. 2019. PMID: 30762114. doi:10.1007/s00330-019-06027-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。