妊娠期大血管缺血性卒中机械取栓术所致的胎儿辐射暴露
本文报告英国三家三级神经科学中心收治的3例妊娠期大血管急性缺血性卒中患者行机械取栓的病例,估算母体与胎儿的辐射剂量,并与创伤全身CT及CT肺动脉造影(CTPA)的剂量比较。结果显示,诊断性CT联合机械取栓后母体全身有效剂量显著高于CTPA组(p < 0.05),但与创伤全身CT无显著差异;胎儿估算剂量显著低于创伤全身成像(p < 0.05),与CTPA无差异。作者结论认为,诊断性卒中成像与机械取栓期间胎儿估算剂量相当于或低于急诊情况下的纯诊断性成像。
要点
- 妊娠期大血管急性缺血性卒中行机械取栓时,胎儿估算剂量相当于或低于急诊纯诊断性成像。
- 诊断性CT联合机械取栓后母体全身有效剂量显著高于CTPA(p < 0.05),与创伤全身CT无显著差异。
- 胎儿估算剂量显著低于创伤全身成像(p < 0.05),与CTPA无差异。
核心结论
- 诊断性卒中成像与机械取栓期间胎儿估算剂量相当于或低于急诊情况下的纯诊断性成像。
- 诊断性CT联合机械取栓后母体全身有效剂量显著高于CTPA(p < 0.05),但与创伤全身CT无显著差异。
- 胎儿估算剂量显著低于创伤全身成像(p < 0.05),与CTPA无差异。
研究设计与样本
- 本文为病例报告,报告英国三家三级神经科学中心分别完成的3例妊娠期机械取栓病例,并估算母体与胎儿辐射剂量。
- 将估算剂量与创伤全身CT及CT肺动脉造影(CTPA)检查的剂量进行比较。
诊断标准与关键数值
- 诊断性CT联合机械取栓后母体全身有效剂量显著高于CTPA组(p < 0.05)。
- 诊断性CT联合机械取栓后母体全身有效剂量与创伤全身CT无显著差异。
- 诊断性CT联合机械取栓后胎儿估算剂量显著低于创伤全身成像(p < 0.05)。
- 诊断性CT联合机械取栓后胎儿估算剂量与CTPA成像无差异。
临床应用与阅片要点
- 本文强调技术考虑以最小化操作风险,并报告母体与胎儿估算剂量。
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: There is overwhelming evidence for the clinical benefits that are derived following mechanical thrombectomy in large-vessel acute ischaemic stroke. The risk of stroke is elevated in pregnancy due to many factors. To date, there have been two reports, totalling five patients, who have undergone mechanical thrombectomy in pregnancy, thus demonstrating the feasibility of the procedure; however, there is no data on the radiation exposure to the mother or foetus related to this therapy.
METHODS: We highlight the important technical considerations to minimise the risk of the procedure and report the estimated dose received by mother and foetus. We also compare these doses with those received during whole-body CT in trauma and CT pulmonary angiogram (CTPA) examinations.
RESULTS: Three cases of mechanical thrombectomy were performed at separate tertiary referral neuroscience centres in the UK. Following diagnostic CT and mechanical thrombectomy, the total whole-body effective dose to the pregnant patient was significantly higher than in patients undergoing CTPA (p < 0.05), but not significant different compared to whole-body CT imaging in trauma patients. The estimated dose received by the foetus following diagnostic CT and mechanical thrombectomy was significantly lower than in whole-body imaging in trauma patients at p < 0.05, with no difference in estimated foetal dose compared to CTPA imaging.
CONCLUSION: The estimated doses received by the foetus during diagnostic stroke imaging and mechanical thrombectomy are equivalent to, or less than, purely diagnostic imaging in emergency situations.