动脉自旋标记与动态对比增强磁共振成像鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤及脑转移瘤
研究纳入8例原发性中枢神经系统淋巴瘤、21例高级别胶质瘤和6例脑转移瘤患者,术前行3.0-T MR常规、动脉自旋标记及动态对比增强成像。淋巴瘤的rCBF显著低于高级别胶质瘤和转移瘤,而Ktrans和Ve显著更高;Ktrans与rCBF鉴别淋巴瘤的AUC分别为0.880和0.889,两者联合AUC提高至0.986。
要点
- 原发性中枢神经系统淋巴瘤的rCBF显著低于高级别胶质瘤和脑转移瘤。
- 淋巴瘤的Ktrans和Ve显著高于高级别胶质瘤和脑转移瘤。
- rCBF联合Ktrans鉴别淋巴瘤的AUC达0.986,优于单一参数。
核心结论
- rCBF和Ktrans是鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤及脑转移瘤的有用参数,两者联合可进一步提高诊断效能。
研究设计与样本
- 研究纳入8例原发性中枢神经系统淋巴瘤、21例高级别胶质瘤和6例脑转移瘤患者,术前行3.0-T MR常规、动脉自旋标记及动态对比增强成像。
关键影像表现/征象
- 原发性中枢神经系统淋巴瘤的rCBF显著低于高级别胶质瘤和脑转移瘤。
- 原发性中枢神经系统淋巴瘤的Ktrans和Ve显著高于高级别胶质瘤和脑转移瘤。
诊断标准与关键数值
- Ktrans鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤及脑转移瘤的AUC为0.880。
- rCBF鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤及脑转移瘤的AUC为0.889。
- rCBF联合Ktrans鉴别原发性中枢神经系统淋巴瘤的AUC为0.986。
临床应用与阅片要点
- rCBF和Ktrans可用于鉴别原发性中枢神经系统淋巴瘤与高级别胶质瘤及脑转移瘤。
- 联合rCBF与Ktrans可提高对原发性中枢神经系统淋巴瘤的诊断效能。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Conventional magnetic resonance imaging (MRI) is sometimes difficult to distinguish primary central nervous system lymphoma (PCNSL) from other malignant brain tumors effectively. The study aimed to evaluate the diagnostic performance of arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE)-derived permeability parameters to differentiate PCNSL from high-grade glioma (HGG) and brain metastasis.
MATERIALS AND METHODS: Eight patients with PCNSL, twenty one patients with HGG and six brain metastasis underwent preoperative 3.0-T MR imaging including conventional, ASL and DCE. Quantitative parameters including relative cerebral blood flow (rCBF), extravascular extracellular volume fraction (Ve) and the volume transfer constant (Ktrans) among PCNSL, HGG and metastasis were compared with a one-way analysis of variance. In addition, the area under the receiver-operating characteristic (ROC) curve (AUC) was constructed to evaluate the differentiation diagnostic performance of each parameter and the combination.
RESULTS: The PCNSL demonstrated significantly lower rCBF, higher Ktrans and Ve compared with HGG and metastasis. For the ROC analyses, both Ktrans and rCBF had good diagnostic performance for discriminating PCNSL from HGG and metastasis, with the AUC of 0.880 and 0.889. With the combination of rCBF and Ktrans, the diagnostic ability for PCNSL was improved with AUC of 0.986.
CONCLUSION: rCBF and Ktrans are useful parameters for differentiating PCNSL from HGG and brain metastasis. The combination of rCBF and Ktrans further helps to improve the diagnostic performance of PCNSL.
引用
- Xi YB, Kang XW, Wang N, et al. Differentiation of primary central nervous system lymphoma from high-grade glioma and brain metastasis using arterial spin labeling and dynamic contrast-enhanced magnetic resonance imaging. Eur J Radiol. 2019. PMID: 30777220. doi:10.1016/j.ejrad.2019.01.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。