动态对比增强MR成像与增强后血管壁成像在检测高危颅内动脉瘤中的互补作用
本研究对29例未破裂囊状颅内动脉瘤患者行增强前后血管壁MR成像及同步动态对比增强MR成像,测量瘤壁及正常颅内动脉的传输常数Ktrans。动脉瘤Ktrans高于正常动脉且与瘤径和PHASES评分相关;瘤壁强化见于66%动脉瘤,与Ktrans无显著相关。随访中2例破裂动脉瘤均有Ktrans升高,仅1例基线有瘤壁强化。
要点
- 动脉瘤Ktrans高于正常颅内动脉,且与动脉瘤大小相关。
- 瘤壁强化见于66%动脉瘤,与Ktrans无显著相关,二者提供互补信息。
- 随访破裂的2例动脉瘤基线均有Ktrans升高,仅1例有瘤壁强化。
核心结论
- 动态对比增强MR成像显示颅内动脉瘤旁Ktrans升高,且独立于增强后血管壁MR成像上的瘤壁强化;动态对比增强MR成像显示的瘤壁通透性增高可为颅内动脉瘤风险评估提供新信息。
研究设计与样本
- 对未破裂囊状颅内动脉瘤患者行增强前后血管壁MR成像,并在注射对比剂同时以3D T1加权 spoiled gradient-echo 成像行动态对比增强MR成像,测量动脉瘤旁及正常颅内动脉旁的传输常数Ktrans;共分析29例受试者(平均年龄53.9±13.5岁,24%为男性,PHASES评分中位数8,四分位距4.75-10)。
关键影像表现/征象
- 动脉瘤Ktrans高于正常颅内动脉(中位数0.0110,四分位距0.0060-0.0390 min-1 vs 中位数0.0032,四分位距0.0018-0.0048 min-1,P < .001)。
- Ktrans与颅内动脉瘤大小相关(Spearman ρ = 0.54,P = .002),与PHASES评分相关(ρ = 0.40,P = .30)。
- 瘤壁强化见于19个(66%)动脉瘤,与颅内动脉瘤大小及PHASES评分相关,但与Ktrans无显著相关(P = .30)。
- 随访期间9例接受保守治疗的患者中2例动脉瘤破裂,2例破裂动脉瘤基线Ktrans均升高,仅1例基线有瘤壁强化。
诊断标准与关键数值
- 以动态对比增强MR成像测量的传输常数Ktrans评估动脉瘤壁通透性,动脉瘤Ktrans中位数0.0110 min-1(四分位距0.0060-0.0390)vs 正常颅内动脉0.0032 min-1(四分位距0.0018-0.0048),P < .001。
- 以增强后血管壁MR成像评估瘤壁强化,19个(66%)动脉瘤见瘤壁强化。
- Ktrans与动脉瘤大小的相关系数Spearman ρ = 0.54(P = .002),与PHASES评分的相关系数ρ = 0.40(P = .30)。
临床应用与阅片要点
- 动态对比增强MR成像所测Ktrans与增强后血管壁成像的瘤壁强化无显著相关,提示二者反映的瘤壁特性不同、可互补。
- 作者认为动态对比增强MR成像显示的瘤壁通透性增高可为颅内动脉瘤风险评估提供新信息。
局限性
- Ktrans与PHASES评分的相关系数ρ = 0.40,P = .30,未达统计学显著。
- 瘤壁强化与Ktrans无显著相关(P = .30)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Individual assessment of the absolute risk of intracranial aneurysm rupture remains challenging. Emerging imaging techniques such as dynamic contrast-enhanced MR imaging and postcontrast vessel wall MR imaging may improve risk estimation by providing new information on aneurysm wall properties. The purpose of this study was to investigate the relationship between aneurysm wall permeability on dynamic contrast-enhanced MR imaging and aneurysm wall enhancement on postcontrast vessel wall MR imaging in unruptured intracranial aneurysms.
MATERIALS AND METHODS: Patients with unruptured saccular intracranial aneurysms were imaged with vessel wall MR imaging before and after gadolinium contrast administration. Dynamic contrast-enhanced MR imaging was performed coincident with contrast injection using 3D T1-weighted spoiled gradient-echo imaging. The transfer constant (K trans) was measured adjacent to intracranial aneurysm and adjacent to the normal intracranial artery.
RESULTS: Twenty-nine subjects were analyzed (mean age, 53.9 ± 13.5 years; 24% men; PHASES score: median, 8; interquartile range, 4.75-10). K trans was higher in intracranial aneurysms compared with the normal intracranial artery (median, 0.0110; interquartile range, 0.0060-0.0390 versus median, 0.0032; interquartile range, 0.0018-0.0048 min-1; P < .001), which correlated with intracranial aneurysm size (Spearman ρ = 0.54, P = .002) and PHASES score (ρ = 0.40, P = .30). Aneurysm wall enhancement, detected in 19 (66%) aneurysms, was associated with intracranial aneurysm size and the PHASES score but not significantly with K trans (P = .30). Aneurysms of 2 of the 9 patients undergoing conservative treatment ruptured during 1-year follow-up. Both ruptured aneurysms had increased K trans, whereas only 1 had aneurysm wall enhancement at baseline.
CONCLUSIONS: Dynamic contrast-enhanced MR imaging showed increased K trans adjacent to intracranial aneurysms, which was independent of aneurysm wall enhancement on postcontrast vessel wall MR imaging. Increased aneurysm wall permeability on dynamic contrast-enhanced MR imaging provides new information that may be useful in intracranial aneurysm risk assessment.
引用
- Qi H, Liu X, Liu P, et al. Complementary Roles of Dynamic Contrast-Enhanced MR Imaging and Postcontrast Vessel Wall Imaging in Detecting High-Risk Intracranial Aneurysms. AJNR Am J Neuroradiol. 2019. PMID: 30792252. doi:10.3174/ajnr.A5983
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。