稀释Onyx技术栓塞脑动静脉畸形的初步经验
本文描述一种使用稀释Onyx栓塞技术治疗脑动静脉畸形的高效方法,对15例脑动静脉畸形患者(男10例、女5例,年龄11–44岁)行稀释Onyx栓塞,平均估计体积缩小90%(范围55–100%),6例畸形完全闭塞,无功能相关并发症;作者认为该技术可能有助于常规Onyx栓塞,但需进一步工作验证。
要点
- 15例脑动静脉畸形患者经16条动脉供血支行15次稀释Onyx栓塞,6例畸形完全闭塞。
- 当反流长度达2 cm(或接近预定长度)且栓子经多轮「注射-反流-等待」仍无法向远端推进时,将常规Onyx 18更换为稀释Onyx。
- 平均估计体积缩小90%(范围55–100%),12例见栓子顺行流入畸形团,3例失败,无功能相关并发症。
核心结论
- 稀释Onyx技术可能作为常规Onyx栓塞的有用辅助手段,使更多栓塞材料进入动静脉畸形团,但作者指出需进一步工作验证该技术。
研究设计与样本
- 15例脑动静脉畸形患者(男10例、女5例;年龄范围11–44岁)接受稀释Onyx技术栓塞,先以常规Onyx-18初始栓塞,再经同一微导管注入稀释Onyx(1.5 mL Onyx-18加0.5 mL DMSO稀释),分析技术操作、血管造影与临床结局;共行15次栓塞、经16条动脉供血支。
关键影像表现/征象
- 12例观察到栓塞材料顺行流入畸形团,3例失败。
- 平均估计体积缩小90%(范围55–100%),6例动静脉畸形完全闭塞。
- 无功能相关并发症发生。
诊断标准与关键数值
- 更换为稀释Onyx的时机:反流长度达2 cm(或接近预定长度)且经多轮「注射-反流-等待」后栓塞材料仍无法向远端推进。
- 稀释Onyx配制:1.5 mL Onyx-18加0.5 mL DMSO稀释。
- 每例患者经单一供血支尝试稀释Onyx一次,仅1例经置于两条供血支的双微导管同时行稀释Onyx栓塞。
临床应用与阅片要点
- 作者描述的操作流程为:先以常规Onyx-18初始栓塞,出现既定反流且栓子无法向远端推进时经同一微导管换用稀释Onyx。
- 作者认为稀释Onyx技术可能作为常规Onyx栓塞的有用辅助,使更多栓塞材料进入畸形团,但指出需进一步工作验证。
局限性
- 作者在结论中自述该技术需额外工作加以验证(additional work is needed to validate this technique)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Insufficient nidus occlusion is a matter of great concern to routine Onyx embolization of brain arteriovenous malformations (AVMs). This paper described an efficient method which using the diluted Onyx embolization technique to treat brain AVM.
METHODS: The diluted Onyx technique was performed in a series of 15 patients with brain AVMs (10 males, 5 females; age range, 11-44 years). It consists of initial embolization with routine Onyx-18, followed by the diluted Onyx (1.5 mL of Onyx-18 diluted with 0.5 mL of DMSO) through the same microcatheter. The technical skills and angiographic and clinical outcomes were analyzed.
RESULTS: A total of 15 embolization sessions were performed with diluted Onyx via 16 arterial feeders in these 15 patients. Each patient underwent one attempt of diluted Onyx through a single feeder except one patient. In this patient, the AVM was simultaneously embolized with diluted Onyx through double microcatheters which were placed in two feeders. When the length of reflux reached to 2 cm (or close to the determined length) and the embolic material could not move distally any more despite some rounds of "injection-reflux-waiting," regular Onyx 18 was changed to diluted Onyx. Antegrade flow of embolic material into the nidus was observed in 12 cases but failed in 3. An average of 90% (range 55-100%) estimated size reduction was achieved, and 6 AVMs were completely obliterated. No functionally relevant complications occurred.
CONCLUSION: The diluted Onyx technique could be a useful adjunct to routine Onyx embolization which may offer more embolic material penetrating into the nidus of AVM, but additional work is needed to validate this technique.
引用
- Xu H, Wang L, Guan S, et al. Embolization of brain arteriovenous malformations with the diluted Onyx technique: initial experience. Neuroradiology. 2019. PMID: 30712140. doi:10.1007/s00234-019-02176-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。