磁靶向微泡联合超声溶栓的体外研究
本研究在部分闭塞大脑中动脉血流模型中,将猪全血血栓暴露于组织型纤溶酶原激活剂、磁靶向微泡和超声联合处理,磁靶向使溶栓速率平均提高三倍,且溶栓速率与声发射总能量呈线性相关。
要点
- 磁靶向使溶栓速率平均提高三倍。
- 溶栓速率与声发射总能量呈线性相关。
- 磁靶向通过单块永磁体实现,血栓区域磁场0.08-0.38 T、梯度12-140 T/m。
核心结论
- 磁靶向微泡可提高体外超声溶栓的溶栓速率,且溶栓速率与声发射总能量线性相关。
研究设计与样本
- 体外研究,将回缩的猪全血血栓置于部分闭塞大脑中动脉血流模型中,联合组织型纤溶酶原激活剂(0.75 µg/mL)、磁性微泡(约10^7个/mL)和超声(0.5 MHz,630 kPa峰值负压,0.2 Hz脉冲重复频率,2%占空比),用单块永磁体实现磁靶向。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Microbubble-enhanced sonothrombolysis is a promising approach to increasing the tolerability and efficacy of current pharmacological treatments for ischemic stroke. Maintaining therapeutic concentrations of microbubbles and drugs at the clot site, however, poses a challenge. The objective of this study was to investigate the effect of magnetic microbubble targeting upon clot lysis rates in vitro. Retracted whole porcine blood clots were placed in a flow phantom of a partially occluded middle cerebral artery. The clots were treated with a combination of tissue plasminogen activator (0.75 µg/mL), magnetic microbubbles (∼107 microbubbles/mL) and ultrasound (0.5 MHz, 630-kPa peak rarefactional pressure, 0.2-Hz pulse repetition frequency, 2% duty cycle). Magnetic targeting was achieved using a single permanent magnet (0.08-0.38 T and 12-140 T/m in the region of the clot). The change in clot diameter was measured optically over the course of the experiment. Magnetic targeting produced a threefold average increase in lysis rates, and linear correlation was observed between lysis rate and total energy of acoustic emissions.
引用
- de Saint Victor M, Barnsley LC, Carugo D, et al. Sonothrombolysis with Magnetically Targeted Microbubbles. Ultrasound Med Biol. 2019. PMID: 30773375. doi:10.1016/j.ultrasmedbio.2018.12.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。