眼科超声检查建议:第一部分——超生物显微镜检查
本文介绍超生物显微镜检查这一最新超声成像方法,其分辨率可显示受检组织结构;文章阐述设备结构与工作原理、在眼球超声检查中的地位、检查技术与诊断各阶段操作规范,并基于长期经验列出适应证与禁忌证,指出超高频探头可显示虹膜后区域。
要点
- 超高频超声探头可显示虹膜后区域,该区域用其他诊断方法无法诊断。
- 医学影像超声频率范围为2至80 MHz,最高频率用于眼球前段成像。
- 适应证涵盖眼球前段疾病与发育异常,印证该方法的特殊意义。
核心结论
- 超高频超声探头的引入使眼球前段虹膜后区域得以可视化,该区域用其他诊断方法无法诊断。
- 涵盖眼球前段疾病与发育异常的广泛诊断适应证,印证了该方法的特殊意义。
研究设计与样本
- 本文为J Ultrason发布的眼科超声检查建议第一部分,聚焦超生物显微镜检查。
- 文章基于作者长期超生物显微镜检查经验,分享该方法的实践方面观察。
诊断标准与关键数值
- 医学影像所用超声频率范围为2至80 MHz,最高频率应用于眼球前段医学成像。
- 超生物显微镜检查的分辨率可对受检组织结构的成像。
临床应用与阅片要点
- 文章讨论了检查技术及诊断各阶段操作规范的作用。
- 文章列出了超生物显微镜诊断的适应证与禁忌证。
- 文章强调新超声诊断工具制造者、软件IT专家与工具使用者之间合作不足,导致这些套件组件之间缺乏一致性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Range of ultrasounds used in medical imaging is between 2 and 80 MHz. The highest frequencies are applied in medical imaging of an anterior segment of an eyeball. This paper covers the newest method of ultrasound imaging - an ultrabiomicroscopic examination. Its name reflects resolution which has so far been unavailable, and which allows for imaging a structure of the examined tissues. The article includes basic information about the structure and principles of operation of ultrabiomicroscopic examination tools. Moreover, its position among other methods for echographic examination of an eyeball was determined. Examination techniques and the role of standards of conduct at each stage of a diagnostic procedure were discussed. A role of insufficient cooperation between constructors of new ultrasonographic diagnostic tools and software IT specialist with the users of these tools, which results in the lack of consistency between the components of these sets was emphasized. Based on long term experience in ultrabiomicroscopic examinations, the authors shared observations on practical aspects of this method. Finally, indications and contraindications for ultrabiomicroscopic diagnostics were listed. Introduction of an ultrahigh frequency ultrasound probe allowed for the visualization of an post-iridial area of an anterior segment of an eyeball - an area whose diagnosis is impossible with other diagnostic methods. A wide spectrum of diagnostic indications, which covers both diseases and development anomalies of an anterior segment of an eyeball, confirms a special meaning of this method. Range of ultrasounds used in medical imaging is between 2 and 80 MHz. The highest frequencies are applied in medical imaging of an anterior segment of an eyeball. This paper covers the newest method of ultrasound imaging – an ultrabiomicroscopic examination. Its name reflects resolution which has so far been unavailable, and which allows for imaging a structure of the examined tissues. The article includes basic information about the structure and principles of operation of ultrabiomicroscopic examination tools. Moreover, its position among other methods for echographic examination of an eyeball was determined. Examination techniques and the role of standards of conduct at each stage of a diagnostic procedure were discussed. A role of insufficient cooperation between constructors of new ultrasonographic diagnostic tools and software IT specialist with the users of these tools, which results in the lack of consistency between the components of these sets was emphasized. Based on long term experience in ultrabiomicroscopic examinations, the authors shared observations on practical aspects of this method. Finally, indications and contraindications for ultrabiomicroscopic diagnostics were listed. Introduction of an ultrahigh frequency ultrasound probe allowed for the visualization of an post-iridial area of an anterior segment of an eyeball – an area whose diagnosis is impossible with other diagnostic methods. A wide spectrum of diagnostic indications, which covers both diseases and development anomalies of an anterior segment of an eyeball, confirms a special meaning of this method.
引用
- Kosmala J, Grabska-Liberek I, Stanislovas Ašoklis R, et al. Recommendations for ultrasound examination in ophthalmology. Part I: Ultrabiomicroscopic examination. J Ultrason. 2018. PMID: 30763020. doi:10.15557/JoU.2018.0050
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。