指南与共识甲状腺与浅表头颈US

甲状腺超声报告:缺陷与建议

Thyroid Ultrasound Reports: Deficiencies and Recommendations.
指南 / 共识 · Med Princ Pract · 2019-02-10

该回顾性研究评估了182份甲状腺超声报告对结节特征的记录完整性,发现仅23.6%报告了三维径线、33.5%报告了具体位置,恶性征象报告率低,无报告包含高宽比,结论认为尽管模板易得,报告仍不完整且不一致。

要点

  • 甲状腺超声报告普遍未完整记录结节三维径线、位置及恶性征象,高宽比无一报告。
  • 仅23.6%结节报告三维径线,33.5%结节具体定位,回声、血供、边缘、钙化报告率均低。
  • 单结节同时报告≥4个特征的比例为0,提示报告模板使用不足。

核心结论

  • 尽管模板易于获取,甲状腺结节超声报告仍不完整且不一致,浪费了本可用于及时医疗决策和患者随访的重要工具。

研究设计与样本

  • 回顾性研究,纳入1年内200份甲状腺超声报告,排除18份后评估182份,分析结节大小、三维径线、位置及五个恶性征象的报告情况。

关键影像表现/征象

  • 所有报告结节均可按大小是否≥1 cm分层,但仅23.6%报告三维径线,33.5%报告具体位置。
  • 回声报告率50%,血供19.2%,边缘10.4%,钙化9.3%,高宽比无报告。
  • 每结节报告1个特征累积频率84%,2个特征27%,3个特征4.4%,≥4个特征为0。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Thyroid ultrasound plays a major role in the clinical management of patients with thyroid nodules. Comprehensive reporting enables malignant risk stratification and biopsy decisions. In this study, we aimed at a systematic evaluation of the content and completeness of thyroid radiology reports.

METHODS: A retrospective study was undertaken. A total of 200 thyroid ultrasound reports of examinations performed over a 1-year period were reviewed. After excluding 18 reports, the remaining 182 were evaluated for the inclusion of the following nodule characteristics: size, 3-axis dimensions, location, presence or absence of five signs suspicious of malignancy, namely microcalcification, hypoechogenecity, irregular margin, height-to-width ratio, and intranodular vascularity.

RESULTS: While all reported nodules could be stratified easily as being more or less than 1 cm in size, only 23.6% of these nodules were reported in 3 dimensions, and 33.5% of the nodules were specifically localized. For any described nodule, the frequency of reporting on echogenicity was 50%, on vascularity 19.2%, on margin 10.4%, on calcifications 9.3%, and no report contained a description of the height-to-width ratio. The cumulative frequency of reporting on one characteristic per nodule was 84%, of two characteristics 27%, three characteristics 4.4%, and no report included ≥4 characteristics per nodule.

CONCLUSION: Despite easily accessible templates, reporting of thyroid nodule sonogram continues to be incomplete and inconsistent. This in turn constitutes a waste of a significant tool that could otherwise help in making timely informed medical decisions and in providing a significant platform for patients' future follow-up.

来源:Med Princ Pract,查看原文。版权归原作者所有。

引用

  1. Qadan L, Ahmed A, Kapila K, et al. Thyroid Ultrasound Reports: Deficiencies and Recommendations. Med Princ Pract. 2019. PMID: 30739108. doi:10.1159/000497789

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。