颈动脉血管壁与动脉粥样硬化斑块的可视化:T1-SPACE与压缩感知T1-SPACE的比较
这项回顾性研究纳入43例接受颈动脉MRI的患者,比较传统T1-SPACE与原型压缩感知T1-SPACE对颈动脉斑块和血管壁的可视化质量。结果显示CS-T1-SPACE对斑块(p=0.0212)和血管壁(p<0.001)的可视化评分显著更高,斑块信号强度比无显著差异(p=0.5971),Spearman相关系数为0.884(p<0.0001),扫描时间加速2.5倍而图像质量相当。作者认为CS-T1-SPACE在评估颈动脉血管壁方面有前景。
要点
- CS-T1-SPACE对颈动脉斑块和血管壁的可视化评分显著高于T1-SPACE。
- 两种序列的斑块信号强度比无显著差异,Spearman相关系数为0.884。
- CS-T1-SPACE扫描时间加速2.5倍,图像质量相当。
核心结论
- CS-T1-SPACE在评估颈动脉斑块和血管壁时较T1-SPACE获得更好的可视化评分和清晰度,扫描时间加速2.5倍且图像质量相当;作者认为CS-T1-SPACE作为颈动脉血管壁检查方法有前景,可提供更好图像质量并缩短采集时间。
研究设计与样本
- 回顾性研究,经机构审查委员会批准,纳入43例患者(男36例,女7例;平均年龄71岁),均接受包含T1-SPACE和CS-T1-SPACE的颈动脉MRI;采用5分制评估斑块和血管壁可视化质量,测量斑块信号强度比并以邻近胸锁乳突肌归一化。
诊断标准与关键数值
- 使用5分制评估颈动脉斑块和血管壁的可视化质量;斑块信号强度比以邻近胸锁乳突肌归一化;可视化评分比较采用Wilcoxon符号秩检验,信号强度比比较亦采用Wilcoxon符号秩检验,相关性采用Spearman相关系数。
临床应用与阅片要点
- 作者认为CS-T1-SPACE作为颈动脉血管壁检查方法有前景,可提供更好图像质量并缩短采集时间;生理性运动如吞咽、动脉搏动和呼吸会在血管壁成像中产生运动伪影,更短的采集时间可减少生理运动所致伪影。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare visualization of carotid plaques and vessel walls between 3D T1-fast spin echo imaging with conventional SPACE (T1-SPACE) and with a prototype compressed sensing T1-SPACE (CS-T1-SPACE) METHODS: This retrospective study was approved by the institutional review board. Participants comprised 43 patients (36 males, 7 females; mean age, 71 years) who underwent carotid MRI including T1-SPACE and CS-T1-SPACE. The quality of visualization for carotid plaques and vessel walls was evaluated using a 5-point scale, and signal intensity ratios (SRs) of the carotid plaques were measured and normalized to the adjacent sternomastoid muscle. Scores for the quality of visualization were compared between T1-SPACE and CS-T1-SPACE using the Wilcoxon signed-rank test. Statistical differences between SRs of plaques with T1-SPACE and CS-T1-SPACE were also evaluated using the Wilcoxon signed-rank test, and Spearman's correlation coefficient was calculated to investigate correlations.
RESULTS: Visualization scores were significantly higher for CS-T1-SPACE than for T1-SPACE when evaluating carotid plaques (p = 0.0212) and vessel walls (p < 0.001). The SR of plaques did not differ significantly between T1-SPACE and CS-T1-SPACE (p = 0.5971). Spearman's correlation coefficient was significant (0.884; p < 0.0001).
CONCLUSIONS: CS-T1-SPACE allowed better visualization scores and sharpness compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. CS-T1-SPACE appears promising as a method for investigating carotid vessel walls, offering better image quality with a shorter acquisition time.
KEY POINTS: • CS-T1-SPACE allowed better visualization compared with T1-SPACE in evaluating carotid plaques and vessel walls, with a 2.5-fold accelerated scan time with comparable image quality. • CS-T1-SPACE offers a promising method for investigating carotid vessel walls due to the better image quality with shorter acquisition time. • Physiological movements such as swallowing, arterial pulsations, and breathing induce motion artifacts in vessel wall imaging, and a shorter acquisition time can reduce artifacts from physiological movements.
引用
- Okuchi S, Fushimi Y, Okada T, et al. Visualization of carotid vessel wall and atherosclerotic plaque: T1-SPACE vs. compressed sensing T1-SPACE. Eur Radiol. 2018. PMID: 30523455. doi:10.1007/s00330-018-5862-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。