文献速递骨肌技术与安全US

肌肉力量与青年及老年人肌肉组织异质性模型估计之间的关联

Association Between Muscle Strength and Modeling Estimates of Muscle Tissue Heterogeneity in Young and Old Adults.
PubMed 文献 · J Ultrasound Med · 2018-12-12

研究纳入33名社区居住的年轻和年长参与者,对股直肌行B型超声定量扫描并测握力;年轻组灰阶值与峰值握力相关(R²=0.36,P<.008),而年长组负二项离散参数k(校正R²=0.70,P<.001)和伽马形状参数α(校正R²=0.68,P<.01)与峰值握力关联最强。

要点

  • 年长组负二项离散参数k(校正R²=0.70)和伽马形状参数α(校正R²=0.68)与握力关联最强。
  • 年轻组灰阶值与峰值握力显著相关(R²=0.36,P<.008)。
  • 伽马混合模型对灰阶直方图拟合最佳(χ²拟合优度=62),Nakagami分布拟合最差(χ²=2595)。

核心结论

  • 负二项离散参数k和伽马形状参数α对评估年龄相关肌肉变化具有临床相关性。
  • 统计模型估计的肌肉异质性在社区居住老年人样本中可能比灰阶测量更好地刻画肌肉组织构成与力量的关联。

研究设计与样本

  • 横断面研究,33名社区居住参与者分为年轻组和年长组。
  • 对股直肌行定量B型超声扫描并完成等长握力测试。
  • 将负二项分布、Nakagami分布、伽马分布和伽马混合模型的形状或离散参数拟合至灰阶直方图。

关键影像表现/征象

  • 年轻组和年长组的灰阶直方图统计模型形状和离散参数存在显著差异(P=.002-.006)。

诊断标准与关键数值

  • 伽马混合模型对灰阶直方图拟合最佳(χ²拟合优度=62),Nakagami分布拟合最差(χ²拟合优度=2595)。
  • 年轻组灰阶值与峰值握力显著相关(R²=0.36;P<.008)。
  • 年长组负二项离散参数k与峰值握力关联最高(校正R²=0.70;P<.001)。
  • 年长组伽马形状参数α与峰值握力关联(校正R²=0.68;P<.01)。

临床应用与阅片要点

  • 在评估年龄相关肌肉变化时,可考虑采用负二项离散参数k和伽马形状参数α作为灰阶分析的补充指标(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Assessing aging muscle through estimates of muscle heterogeneity may overcome some of the limitations of grayscale analyses. The objectives of this study included determining statistical model parameters that characterize muscle echogenicity and are associated with strength in younger and older participants.

METHODS: Thirty-three community-dwelling participants were assigned to younger and older groups. Quantitative B-mode ultrasound scanning of the rectus femoris and isometric grip strength testing were completed. Shape or dispersion parameters from negative binomial distribution, Nakagami, gamma, and gamma mixture models were fitted to the grayscale histograms.

RESULTS: The mean ages ± SDs of the younger and older groups were 24.0 ± 2.3 and 65.1 ± 6.5 years, respectively. Statistical model shape and dispersion parameters for the grayscale histograms significantly differed between the younger and older participants (P = .002-.006). Among all of the statistical models considered, the gamma mixture model showed the best fit with the grayscale histograms (χ2 goodness of fit = 62), whereas the Nakagami distribution displayed the poorest fit (χ2 goodness of fit = 2595). Grayscale values were significantly associated with peak grip strength force in younger adult participants (R2 = 0.36; P < .008). However, the negative binomial dispersion parameter k (adjusted R2 = 0.70; P < .001) and gamma shape parameter α (adjusted R2 = 0.68; P < .01) showed the highest associations with peak grip strength force in older adult participants.

CONCLUSIONS: The negative binomial dispersion parameter k and the gamma shape parameter α have clinical relevance for the assessment of age-related muscle changes. Statistical models of muscle heterogeneity may characterize the association between muscle tissue composition estimates and strength better than grayscale measures in samples of community-dwelling older adults.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Harris-Love MO, Gonzales TI, Wei Q, et al. Association Between Muscle Strength and Modeling Estimates of Muscle Tissue Heterogeneity in Young and Old Adults. J Ultrasound Med. 2018. PMID: 30548644. doi:10.1002/jum.14864

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。