高分辨率平板CT与3-T磁共振关节造影在腕关节的初步活体对比研究
本研究对49例临床怀疑腕关节病变的患者行三腔室腕关节造影,比较高分辨率C臂平板CT关节造影(FPCT-A)与3-T磁共振关节造影(MR-A)的诊断性能。结果显示FPCT-A对所有解剖结构的图像质量评分均显著优于MR-A(p<0.001),伪影评分MR-A低于FPCT-A(p<0.001),且FPCT-A流程更省时;作者认为对需专门显示腕关节内在结构的患者可考虑FPCT-A。
要点
- FPCT-A对腕关节内在韧带、TFCC、软骨、软骨下骨及骨小梁的图像质量均显著优于3-T MR-A(p<0.001)。
- 图像质量差异最大见于软骨(2.0),最小见于TFCC(0.9)。
- MR-A的伪影评分低于FPCT-A(p<0.001),但FPCT-A流程更省时。
核心结论
- 腕关节FPCT-A较MR-A提供更优的图像质量和更高效的流程。
- 作者认为,对计划行腕关节内在结构专门成像的患者可考虑FPCT-A。
研究设计与样本
- 研究为活体初步对比研究,纳入49例临床怀疑腕关节病变的患者。
- 所有患者行三腔室腕关节造影,FPCT-A采用高分辨率采集模式,随后使用专用腕线圈行3-T MR检查。
- 对FPCT-A与MR-A的图像质量和伪影按解剖结构可显示性进行评估,并记录不同图像采集的时间戳用于流程评估。
关键影像表现/征象
- FPCT-A对所有结构的图像质量评分均显著优于MR-A(p<0.001),包括内在韧带、TFCC、软骨、软骨下骨和骨小梁。
- 图像质量差异最大见于软骨(2.0),最小见于TFCC(0.9)。
临床应用与阅片要点
- 作者认为,对计划行腕关节内在结构专门成像的患者可考虑FPCT-A。
- 阅片时需注意FPCT-A的伪影评分高于MR-A(p<0.001),而MR-A伪影较少。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The objective of this study was to compare the diagnostic performance of direct C-arm flat panel computed tomography arthrography (FPCT-A) with direct magnetic resonance arthrography (MR-A) of the wrist in patients with clinically suspected pathologies.
METHODS: Forty-nine patients underwent tri-compartmental wrist arthrography. FPCT-A was acquired using a high-resolution acquisition mode, followed by a 3-T MR exam using a dedicated wrist coil. Image quality and artifacts of FPCT-A and MR-A were evaluated with regard to the depictability of anatomical structures. The time stamps for the different image acquisitions were recorded for workflow assessment.
RESULTS: Image quality was rated significantly superior for all structures for FPCT-A (p < 0.001) as compared to MR-A including intrinsic ligaments, TFCC, cartilage, subchondral bone, and trabeculae. The differences in image quality were highest for cartilage (2.0) and lowest for TFCC (0.9). The artifacts were rated lower in MR-A than in FPCT-A (p < 0.001). The procedure was more time-efficient in FPCT-A than in MR-A.
CONCLUSIONS: FPCT-A of the wrist provides superior image quality and optimized workflow as compared to MR-A. Therefore, FPCT-A should be considered in patients scheduled for dedicated imaging of the intrinsic structures of the wrist.
KEY POINTS: • FPCT arthrography allows high-resolution imaging of the intrinsic wrist structures. • The image quality is superior as compared to MR arthrography. • The procedure is more time-efficient than MR arthrography.
引用
- Sonnow L, Koennecker S, Luketina R, et al. High-resolution flat panel CT versus 3-T MR arthrography of the wrist: initial results in vivo. Eur Radiol. 2018. PMID: 30552480. doi:10.1007/s00330-018-5901-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。