家族性高胆固醇血症患者跟腱的灰阶超声与剪切波弹性成像特征:一项初步研究
本研究比较了94条家族性高胆固醇血症(FH)患者跟腱与38条健康对照跟腱的灰阶超声及剪切波弹性成像(SWE)特征,测量近段、中段和远段的厚度与弹性模量。FH组跟腱增厚、弹性模量降低,灰阶图像显示低回声伴线状高回声纤维排列紊乱,两组在三个节段的厚度和弹性模量差异均有统计学意义(均P<0.001)。作者认为灰阶特征与SWE特性可为FH患者跟腱的定量评估提供互补的生物力学信息。
要点
- FH患者跟腱近段、中段、远段厚度均大于健康对照,弹性模量均低于健康对照(均P<0.001)。
- FH组92/94条跟腱呈低回声伴线状高回声纤维排列紊乱,17/94条见钙化。
- 健康对照跟腱呈弥漫低回声伴平行线状高回声条纹,可作为正常参照。
核心结论
- 研究结果提示,FH患者跟腱的灰阶超声特征与SWE特性可为跟腱的定量评估提供互补的生物力学信息。
研究设计与样本
- 初步研究,纳入94条FH患者跟腱与38条健康对照跟腱,行灰阶超声及定量剪切波弹性成像,每條跟腱于近段、中段、远段三个节段纵切面测量厚度、灰阶图像特征及弹性模量。
关键影像表现/征象
- 健康对照跟腱厚度近段(4.46±0.68)mm、中段(5.41±1.01)mm、远段(4.41±0.57)mm,灰阶呈弥漫低回声伴平行线状高回声条纹;FH组厚度近段(7.65±3.09)mm、中段(11.46±4.84)mm、远段(8.14±2.90)mm,灰阶呈低回声伴线状高回声纤维排列紊乱(92/94),2/94条跟腱见局限性明显低回声,17/94条见钙化。
诊断标准与关键数值
- 健康对照弹性模量近段(418.08±43.13)kPa、中段(425.78±47.14)kPa、远段(407.79±38.74)kPa;FH组近段(294.86±58.13)kPa、中段(280.93±63.58)kPa、远段(282.41±56.47)kPa;两组近段、中段、远段厚度及平均弹性模量差异均有统计学意义(均P<0.001)。
临床应用与阅片要点
- 作者认为灰阶超声特征与SWE特性可为FH患者跟腱的定量评估提供互补的生物力学信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To investigate the feasibility of grayscale ultrasound and quantitative shear wave elastography (SWE) for assessing the image features and stiffness of the Achilles tendon in patients with familial hypercholesterolemia (FH) compared with healthy controls.
METHODS: A total of 38 Achilles tendons from healthy control participants and 94 from patients with FH were examined with grayscale ultrasound and SWE. Each Achilles tendon examination was performed on 3 different segments (proximal, middle, and distal). The thickness, grayscale image features and elasticity modulus of each segment was measured on longitudinal views.
RESULTS: In Achilles tendons of healthy control participants, the thicknesses of the proximal, middle, and distal segments were (4.46 ± 0.68) mm, (5.41 ± 1.01) mm, and (4.41 ± 0.57) mm, respectively. The grayscale features were diffusely hypoechoic with parallel linear hyperechoic striations. The mean elasticity modulus of the proximal, middle, and distal sites was (418.08 ± 43.13) kPa, (425.78 ± 47.14) kPa, and (407.79 ± 38.74) kPa, respectively. In the FH group, the thicknesses of the proximal, middle, and distal segments were (7.65 ± 3.09) mm, (11.46 ± 4.84) mm, and (8.14 ± 2.90) mm, respectively. The grayscale features were hypoechoic with linear hyperechoic disordered fibre distribution (92/94). Two of 94 Achilles tendons had considerable focal hypoechogenicity. Seventeen of 94 Achilles tendons had calcifications. In the FH group, the mean elasticity modulus of the proximal, middle, and distal segments were (294.86 ± 58.13) kPa, (280.93 ± 63.58) kPa, and (282.41 ± 56.47) kPa, respectively. Statistically significant differences were found between the Achilles tendons of healthy control participants and FH patients in the thicknesses and mean elasticity modulus at the proximal, middle and distal segments of the Achilles tendons (all P < 0.001).
CONCLUSIONS: Our results suggest that the grayscale features and SWE characteristics of the Achilles tendon provided complementary biomechanical information for quantitative assessment the Achilles tendon in patients with FH.
引用
- Zhang L, Yong Q, Pu T, et al. Grayscale ultrasonic and shear wave elastographic characteristics of the Achilles' tendon in patients with familial hypercholesterolemia: A pilot study. Eur J Radiol. 2018. PMID: 30527289. doi:10.1016/j.ejrad.2018.10.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。