文献速递骨肌US

踝与足超声:小解剖结构左右侧对比的可靠性

Ankle and Foot Ultrasound: Reliability of Side-to-Side Comparison of Small Anatomic Structures.
PubMed 文献 · J Ultrasound Med · 2018-12-28

前瞻性纳入30名健康志愿者,由2名肌骨放射科医生分次双侧评估踝足小结构(深腓神经、伸肌支持带上束、跟腓韧带、腓骨支持带上束、胫骨后肌腱、胫神经、跟腱、跖肌腱、足底筋膜、腓肠神经),评估观察者内与观察者间一致性及侧别差异。结果显示观察者内k=0.67(95%CI 0.57-0.78),观察者间k=0.73(95%CI 0.68-0.77),所有结构平均差异0.36±1.85 mm,总体变异系数18.5%,组内相关系数0.93(95%CI 0.92-0.94)。结论认为健康对侧可作为实时肌骨超声评估小结构的参考。

要点

  • 观察者间一致性k=0.73(95%CI 0.68-0.77),观察者内一致性k=0.67(95%CI 0.57-0.78)。
  • 所有结构左右侧平均差异0.36±1.85 mm,总体变异系数18.5%。
  • 组内相关系数0.93(95%CI 0.92-0.94),提示测量可重复性较高。

核心结论

  • 在踝足超声中,实时肌骨超声评估小结构时可将健康对侧作为参考。

研究设计与样本

  • 前瞻性研究,纳入30名健康志愿者,由2名肌骨放射科医生分次双侧评估踝足小结构,重复30次(100%)检查以评估观察者内和观察者间一致性,使用非参数统计。

诊断标准与关键数值

  • 观察者内一致性k=0.67(95%CI 0.57-0.78)。
  • 观察者间一致性k=0.73(95%CI 0.68-0.77)。
  • 所有结构平均差异0.36±1.85 mm,总体变异系数18.5%。
  • 组内相关系数0.93(95%CI 0.92-0.94)。
  • 数据非正态分布(P > .001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: In sonography of clinically relevant small structures of the ankle and foot, the healthy contralateral side can be used as a reference to identify subtle abnormalities. Intrasubject side-to-side variability must be minimal. The aim of this study was to assess the reliability of side-to-side sonographic evaluation of small structures of the ankle and foot.

METHODS: Thirty healthy volunteers were prospectively studied. Small structures of the ankle and foot were evaluated bilaterally by 2 musculoskeletal radiologists in separate sessions. The deep peroneal nerve, superior extensor retinacula, calcaneofibular ligament, superior peroneal retinacula, tibialis posterior tendon, tibial nerve, Achilles tendon, plantaris tendon, plantar fascia, and sural nerve were considered. To assess intra- and interreader agreements, 30 (100%) examinations were repeated. A nonparametric statistic was used.

RESULTS: Data were not normally distributed (P > .001). Intrareader agreement was k = 0.67 (95% confidence interval, 0.57-0.78) and interreader agreement was k = 0.73 (95% confidence interval, 0.68-0.77). The mean values and standard deviation for all the structures were 0.36 ± 1.85 mm. The overall coefficient of variation was 18.5%. The intraclass correlation coefficient was 0.93 (95% confidence interval, 0.92-0.94).

CONCLUSIONS: In ankle and foot sonography, the healthy contralateral side can be used as a reference during a real-time musculoskeletal ultrasound evaluation of small structures.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Rossi F, Zaottini F, Picasso R, et al. Ankle and Foot Ultrasound: Reliability of Side-to-Side Comparison of Small Anatomic Structures. J Ultrasound Med. 2018. PMID: 30592321. doi:10.1002/jum.14911

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。