文献速递乳腺乳腺X线

数字乳腺X线摄影对英国国家医疗服务体系乳腺癌筛查项目癌症检出率和召回率的影响:1130万次筛查事件

Impact of Digital Mammography on Cancer Detection and Recall Rates: 11.3 Million Screening Episodes in the English National Health Service Breast Cancer Screening Program.
PubMed 文献 · Radiology · 2018-12-11

结果显示数字乳腺X线摄影使总体癌症检出率提高14%(P < .001),召回率几乎不变,1级和2级浸润性癌检出率更高,3级浸润性癌检出率无变化。

要点

  • 数字乳腺X线摄影使总体癌症检出率提高14%(P < .001),召回率几乎不变。
  • 1级和2级浸润性癌(导管癌和小叶癌)检出率更高,3级浸润性癌检出率无变化。
  • 45-52岁首次筛查检出率提高19%(P < .001),53-70岁后续筛查提高13%(P < .001)。

核心结论

  • 数字乳腺X线摄影使总体癌症检出率提高14%,召回率无变化,且未受其他因素变化的混杂影响;1级和2级浸润性癌(包括导管癌和小叶癌)检出率显著增高,但3级浸润性癌检出率无变化。

诊断标准与关键数值

  • 数字乳腺X线摄影总体癌症检出率较屏片乳腺X线摄影提高14%(P < .001)。
  • 45-52岁女性首次筛查检出率提高19%(P < .001),53-70岁女性后续筛查检出率提高13%(P < .001)。
  • 1级和2级浸润性癌(导管癌和小叶癌)检出率更高,3级浸润性癌检出率无变化。
  • 召回率几乎不变。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To report the impact of changing from screen-film mammography to digital mammography (DM) in a large organized national screening program. Materials and Methods A retrospective analysis of prospectively collected annual screening data from 2009-2010 to 2015-2016 for the 80 facilities of the English National Health Service Breast Cancer Screening Program, together with estimates of DM usage for three time periods, enabled the effect of DM to be measured in a study of 11.3 million screening episodes in women aged 45-70 years (mean age, 59 years). Regression models were used to estimate percentage and absolute change in detection rates due to DM. Results The overall cancer detection rate was 14% greater with DM (P < .001). There were higher rates of detection of grade 1 and 2 invasive cancers (both ductal and lobular), but no change in the detection of grade 3 invasive cancers. The recall rate was almost unchanged by the introduction of DM. At prevalent (first) screening episodes for women aged 45-52 years, DM increased the overall detection rate by 19% (P < .001) and for incident screening episodes in women aged 53-70 years by 13% (P < .001). Conclusion The overall cancer detection rate was 14% greater with digital mammography with no change in recall rates and without confounding by changes in other factors. There was a substantially higher detection of grade 1 and grade 2 invasive cancers, including both ductal and lobular cancers, but no change in the detection of grade 3 invasive cancers. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by C.I. Lee and J.M. Lee in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Blanks RG, Wallis MG, Alison R, et al. Impact of Digital Mammography on Cancer Detection and Recall Rates: 11.3 Million Screening Episodes in the English National Health Service Breast Cancer Screening Program. Radiology. 2018. PMID: 30526360. doi:10.1148/radiol.2018181426

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。