侵袭性乳腺癌女性动态增强乳腺MRI上转移性胸骨病变的特征
研究分析了2010年1月至2018年9月间379例乳腺癌患者中因PET-CT或骨扫描发现胸骨异常而接受乳腺MRI的21例,最终14例胸骨转移纳入分析。四位放射科医生回顾性可检出86%(12/14)的转移灶,但仅57%在原始报告中前瞻性描述。不均匀强化、非局限边缘、多发病灶和大小>1 cm与转移相关。
要点
- 乳腺MRI上胸骨转移回顾性可检出率达86%,但前瞻性报告率仅57%。
- 转移性胸骨病变常见T1低信号、T2高信号、不均匀强化和廓清。
- 不均匀强化、非局限边缘、多发和大小>1 cm更常见于转移性病变。
核心结论
- 大多数胸骨转移(86%)在乳腺MRI上回顾性可检出,但仅57%被前瞻性报告,强调在乳腺MRI上评估胸骨的重要性;某些MRI特征可能提示转移。
研究设计与样本
- 回顾性研究,2010年1月至2018年9月间379例乳腺癌患者因PET-CT或骨扫描发现胸骨异常,其中21例在100天内接受乳腺MRI,14例胸骨转移符合纳入标准;由四位放射科医生回顾性判读MRI图像,并与良性对照组比较MRI特征。
关键影像表现/征象
- 12例MRI可检出转移灶中,平均最大径33 mm,7例有>1个病灶,全部T1低信号,11例T2高信号,11例边缘非局限,6例超出骨皮质,11例不均匀强化,11例显示廓清。
诊断标准与关键数值
- 胸骨病变符合以下任一条件视为转移:活检证实转移;病变与同期活检证实的骨转移表现相似;存在大量可疑病变且推测为广泛骨转移。转移组与良性对照组比较:不均匀强化(p=0.002)、非局限边缘(p<0.001)、多发(p=0.005)、大小>1 cm(p<0.001)更常见。
临床应用与阅片要点
- 在乳腺MRI阅片时应评估胸骨,注意T1低信号、T2高信号、不均匀强化、非局限边缘、多发和大小>1 cm等特征可能提示转移。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Detecting sternal lesions is not the purpose of breast MRI, but diagnosing metastasis has major clinical implications. Our purpose was to determine the breast MRI features of sternal metastases detected on PET-CT and bone-scan.
MATERIALS AND METHODS: Between 01/2010-09/2018, 379 patients with breast cancer had sternal findings on PET-CT or bone-scan, 21 of which underwent breast MRI within 100 days. Sternal lesions were considered metastatic if (1) biopsy demonstrated metastasis, (2) the lesion had similar appearance to synchronous sites of biopsy-proven osseous metastases, or (3) there were numerous suspicious lesions in which widespread osseous metastasis was presumed. Four radiologists reviewed the MR images to determine if metastases were retrospectively detectable. MRI reports were reviewed to determine if lesions were prospectively described. MRI features of metastatic sternal lesions were compared to benign controls.
RESULTS: Fourteen sternal metastases met inclusion criteria. Lesions were retrospectively detectable on breast MRI by all radiologists in 86% (12/14) of cases, but prospectively reported in 57%. Of the 12 MRI-detectable metastases, mean maximum dimension was 33 mm, 7 had >1 lesion, all were T1-hypointense, 11 were T2-hyperintense, 11 were noncircumscribed, 6 extended beyond cortex, 11 enhanced heterogeneously, and 11 demonstrated washout. Heterogeneous enhancement (p = 0.002), noncircumscribed margins (p < 0.001), multiplicity (p = 0.005), and size >1 cm (p < 0.001) were more frequent with metastatic compared to benign sternal lesions.
CONCLUSION: Most sternal metastases (86%) were retrospectively detectable on breast MRI, but only 57% were prospectively reported, emphasizing the importance evaluating the sternum on breast MRI. Certain MRI features may raise suspicion for metastasis.
引用
- Lee AY, Navarro R, Busby LP, et al. Characterization of Metastatic Sternal Lesions on Dynamic Contrast-Enhanced Breast MRI in Women with Invasive Breast Cancer. Acad Radiol. 2018. PMID: 30527457. doi:10.1016/j.acra.2018.11.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。