定量三室乳腺图像分析与乳腺X线摄影影像组学联合应用在临床数据集乳腺肿块分类中的获益
前瞻性纳入109例乳腺影像报告和数据系统4类或5类乳腺肿块女性,于活检前获取双能头尾位和内外斜位乳腺X线摄影。水-脂-蛋白三室定量图像分析联合乳腺X线摄影影像组学较常规诊断性数字乳腺X线摄影提高了活检阳性预测值(49% vs 32.1%),并减少35.8%的总活检数。
要点
- 联合定量三室图像分析与乳腺X线摄影影像组学在最大敏感度下活检阳性预测值为49%,常规数字乳腺X线摄影为32.1%。
- 联合方法较常规诊断性数字乳腺X线摄影减少35.8%(39/109)的总活检数。
- 联合方法敏感度为97%(34/35),常规数字乳腺X线摄影敏感度为100%。
核心结论
- 乳腺肿块定量三室乳腺图像分析联合乳腺X线摄影影像组学有潜力减少不必要的乳腺活检。
研究设计与样本
- 前瞻性研究,2013年至2017年纳入109例女性(平均年龄51岁,范围31-85岁),乳腺肿块均为乳腺影像报告和数据系统4类或5类(35例浸润性癌,74例良性)。
- 于活检前即刻获取双能头尾位和内外斜位乳腺X线摄影。
- 利用图像内体模,由高能量和低能量下的衰减计算每个像素的水、脂、蛋白厚度三个定量室。
- 肿块自动分割后,从低能量乳腺X线摄影和定量室图像中提取特征。
- 采用线性判别分类器进行十折交叉验证,使用预设特征签名区分恶性和良性肿块,比较单独水-脂-蛋白成分图像、单独乳腺X线摄影影像组学及两者联合图像分析三种方式。
诊断标准与关键数值
- 主要性能指标为最大敏感度下活检阳性预测值(PPV3),并与常规诊断性数字乳腺X线摄影比较。
- 常规诊断性数字乳腺X线摄影PPV3为32.1%(35/109;95%CI:23.9%,41.3%),敏感度为100%。
- 联合乳腺X线摄影影像组学加定量三室图像分析PPV3为49%(34/70;95%CI:36.5%,58.9%;P < .001),敏感度为97%(34/35;95%CI:90.3%,100%;P < .001)。
- 联合方法较常规诊断性数字乳腺X线摄影减少35.8%(39/109)的总活检数(P < .001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To investigate the combination of mammography radiomics and quantitative three-compartment breast (3CB) image analysis of dual-energy mammography to limit unnecessary benign breast biopsies. Materials and Methods For this prospective study, dual-energy craniocaudal and mediolateral oblique mammograms were obtained immediately before biopsy in 109 women (mean age, 51 years; range, 31-85 years) with Breast Imaging Reporting and Data System category 4 or 5 breast masses (35 invasive cancers, 74 benign) from 2013 through 2017. The three quantitative compartments of water, lipid, and protein thickness at each pixel were calculated from the attenuation at high and low energy by using a within-image phantom. Masses were automatically segmented and features were extracted from the low-energy mammograms and the quantitative compartment images. Tenfold cross-validations using a linear discriminant classifier with predefined feature signatures helped differentiate between malignant and benign masses by means of (a) water-lipid-protein composition images alone, (b) mammography radiomics alone, and (c) a combined image analysis of both. Positive predictive value of biopsy performed (PPV3) at maximum sensitivity was the primary performance metric, and results were compared with those for conventional diagnostic digital mammography. Results The PPV3 for conventional diagnostic digital mammography in our data set was 32.1% (35 of 109; 95% confidence interval [CI]: 23.9%, 41.3%), with a sensitivity of 100%. In comparison, combined mammography radiomics plus quantitative 3CB image analysis had PPV3 of 49% (34 of 70; 95% CI: 36.5%, 58.9%; P < .001), with a sensitivity of 97% (34 of 35; 95% CI: 90.3%, 100%; P < .001) and 35.8% (39 of 109) fewer total biopsies (P < .001). Conclusion Quantitative three-compartment breast image analysis of breast masses combined with mammography radiomics has the potential to reduce unnecessary breast biopsies. © RSNA, 2018 Online supplemental material is available for this article.