文献速递乳腺介入US

真空辅助针吸活检经皮切除乳腺癌患者前哨淋巴结的可行性与可接受性研究

Percutaneous sentinel node removal using a vacuum-assisted needle biopsy in women with breast cancer: a feasibility and acceptability study.
PubMed 文献 · Clin Radiol · 2018-12-07

研究评估双探针与超声引导下经皮大孔径真空辅助活检(VAB)切除腋窝前哨淋巴结的可行性与可接受性。22例患者同意,20例接受操作,18/20(90%)获得放射性标记淋巴结组织,平均操作时间11分钟,18例中4例VAB组织发现转移,腋窝转移灵敏度100%。并发症包括1例气胸,术后即刻血肿常见(14/20),作者认为虽然初步灵敏度与特异度令人鼓舞,但并发症可能阻碍广泛开展。

要点

  • 双探针与超声引导下经皮VAB切除前哨淋巴结技术可行,18/20(90%)获得放射性标记淋巴结组织。
  • VAB切除组织对腋窝转移的灵敏度为100%(4/18例发现转移)。
  • 术后即刻血肿常见(14/20),1例在局部麻醉注射时发生气胸。

核心结论

  • 双扫描引导下VAB切除前哨淋巴结可行;初步灵敏度与特异度令人鼓舞,但并发症可能阻碍广泛实施。

研究设计与样本

  • 可行性研究;22例患者同意,20例接受经皮VAB切除前哨淋巴结;术前一天给予锝纳米胶体,术中联合γ探针与超声识别前哨淋巴结,使用7G VAB装置。

诊断标准与关键数值

  • VAB切除组织对腋窝转移的灵敏度为100%(4/18例发现转移)。

临床应用与阅片要点

  • 作者认为双扫描引导下VAB切除前哨淋巴结可行;但并发症可能阻碍广泛实施。

局限性

  • 作者结论指出并发症可能阻碍广泛实施。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIMS: To assess the feasibility and acceptability of large-gauge percutaneous removal of the axillary sentinel lymph node (SLN) using dual gamma probe and ultrasound guidance.

MATERIALS AND METHODS: Technetium nanocolloid was administered the day before surgery. On the day of surgery, potential SLNs were identified with gamma probe and ultrasound scanning. A 7 G vacuum-assisted biopsy (VAB) device was inserted percutaneously deep to the target node and the node(s) removed. The gamma probe was used to confirm removal of radiolabelled tissue. At surgery, any residual radiolabelled or blue nodes were removed. Morbidity was assessed via (1) a pain questionnaire immediately after the percutaneous procedure, (2) relevant items from the FACT B+4 questionnaire 7-10 days after surgery, and (3) case note review 1 month after surgery.

RESULTS: Twenty-two patients consented and 20 patients underwent the procedure. Radiolabelled nodal tissue was obtained in 18/20 (90%). The mean procedure time was 11 minutes. Four of 18 patients had metastatic disease identified in the VAB excision tissue with 100% sensitivity for axillary metastasis. At axillary surgery, additional intact SLN or fragments were found in 14 patients. No additional metastatic disease was found at surgery. One patient suffered a pneumothorax during instillation of local anaesthetic. The median pain score was 10/100 by visual analogue scale. Immediate post-procedure haematoma was common (14 of 20) and prolonged manual compression frequent.

CONCLUSION: VAB removal of sentinel nodes using dual scanning is feasible. Although preliminary sensitivity and specificity levels are encouraging, complications may discourage widespread implementation.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Evans A, Whelehan P, Warwick V, et al. Percutaneous sentinel node removal using a vacuum-assisted needle biopsy in women with breast cancer: a feasibility and acceptability study. Clin Radiol. 2018. PMID: 30528598. doi:10.1016/j.crad.2018.11.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。