多模态Sound Touch弹性成像鉴别乳腺良恶性肿块的诊断性能
研究纳入159个乳腺肿块(平均大小14.86±6.57 mm,范围5.30-30.00 mm),以病理为诊断标准,评估Young's模量(E)、剪切模量(G)和剪切波(C)鉴别良恶性的能力并获取最佳截断值。9个参数联合分析时,汇总敏感度84%(95%CI 79%-88%)、特异度82%(95%CI 80%-84%)、阳性似然比4.75(95%CI 4.15-5.43)、阴性似然比0.20(95%CI 0.15-0.25)、诊断评分3.19(95%CI 2.84-3.54)、SROC曲线下面积90.2%(95%CI 87%-92%)。结论认为Sound Touch弹性成像可作为鉴别乳腺良恶性肿块的新型超声诊断方法。
要点
- 9个弹性参数联合时汇总敏感度84%、特异度82%、SROC曲线下面积90.2%。
- 各参数诊断价值排序为Gmax > Emax > Cmax > Csd > Esd > Gsd > Emean > Gmean > Cmean。
- Emin、Gmin、Cmin在良恶性肿块间无显著差异。
核心结论
- Sound Touch弹性成像可作为鉴别乳腺良恶性肿块的新型超声诊断方法。
研究设计与样本
- 纳入159个乳腺肿块(平均大小14.86±6.57 mm,范围5.30-30.00 mm),以病理结果为诊断标准,基于ROC曲线评估Young's模量(E)、剪切模量(G)和剪切波(C)鉴别良恶性乳腺肿块的能力并获取最佳截断值。
诊断标准与关键数值
- 9个参数联合时汇总敏感度84%(95%CI 79%-88%)、特异度82%(95%CI 80%-84%)、阳性似然比4.75(95%CI 4.15-5.43)、阴性似然比0.20(95%CI 0.15-0.25)、诊断评分3.19(95%CI 2.84-3.54)、SROC曲线下面积90.2%(95%CI 87%-92%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Evaluating the value of screening breast masses by separate or combined use of multimodal Sound Touch Elastography.
METHODS: Women with 159 masses (mean size, 14.86 ± 6.57 mm; range, 5.30-30.00 mm) were enrolled in the study. The pathology results were adopted as diagnostic standards. The abilities of Young's modulus (E), shear modulus (G), and shear wave (C) to differentiate malignant and benign breast masses based on receiver operating characteristic curves were evaluated, and the optimal cutoff values were obtained. Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were calculated. Then, the values were combined to perform an overall analysis of Sound Touch Elastography using evidence-based medicine, construct forest plots, and calculate areas under the summary receiver operating characteristic curves, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic scores.
RESULTS: A total of 159 masses with a mean size of 14.86 ± 6.57 mm (range, 5.30-30.00 mm) were included. For the various parameters, the diagnostic values were as follows: Gmax > Emax > Cmax > Csd > Esd > Gsd > Emean > Gmean > Cmean . There were no significant differences in Emin , Gmin , or Cmin . When the 9 parameters were combined, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic scores and areas under the summary receiver operating characteristic curves were 84% (95% confidence interval [CI], 79%-88%), 82% (95% CI, 80%-84%), 4.75 (95% CI, 4.15-5.43), 0.20 (95% CI, 0.15-0.25), 3.19 (95% CI, 2.84-3.54) and 90.2% (95% CI, 87%-92%), respectively.
CONCLUSIONS: Sound Touch Elastography can be recognized as a new ultrasound-based diagnostic method for differentiation between benign and malignant breast masses.
引用
- Dong F, Wu H, Zhang L, et al. Diagnostic Performance of Multimodal Sound Touch Elastography for Differentiating Benign and Malignant Breast Masses. J Ultrasound Med. 2018. PMID: 30593673. doi:10.1002/jum.14915
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。