影像组学在乳腺X线摄影乳腺癌诊断中的附加价值:一项可行性研究
本回顾性研究纳入173例乳腺病变患者(74个良性、99个恶性),从乳腺X线图像提取影像组学特征并用四种机器学习算法建模;逻辑回归模型在测试集诊断准确率0.886、特异度0.900、敏感度0.867,均高于两位乳腺放射科医生联合阅片的0.769、0.695、0.858。
要点
- 逻辑回归模型测试集准确率0.886、特异度0.900、敏感度0.867,高于两位放射科医生联合阅片的0.769、0.695、0.858。
- 影像组学可从乳腺X线图像捕获并量化特征,为良恶性乳腺肿瘤提供诊断信息。
- 作者认为影像组学可为放射科医生提供补充信息。
核心结论
- 乳腺X线图像可被影像组学捕获和量化,对良恶性乳腺肿瘤具有良好诊断能力,并为放射科医生提供补充信息。
研究设计与样本
- 回顾性研究,纳入173例在新辅助化疗前接受乳腺X线检查的患者(74个良性、99个恶性病变);提取影像组学特征,经中心化和归一化等预处理及统计分析筛选特征,用支持向量机、逻辑回归、K近邻和贝叶斯分类四种机器学习算法建模,并用独立测试集验证。
诊断标准与关键数值
- 预处理后保留51个影像组学特征;逻辑回归分类在四种模型中区分能力最佳;训练集诊断准确率0.978、特异度0.975、敏感度0.983;测试集诊断准确率0.886、特异度0.900、敏感度0.867。
临床应用与阅片要点
- 两位乳腺放射科医生联合阅片在训练集的准确率0.772、特异度0.710、敏感度0.862,在测试集分别为0.769、0.695、0.858;作者认为影像组学可提供补充信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: This study aimed to evaluate whether radiomics can improve the diagnostic performance of mammography compared with that obtained by experienced radiologists.
METHODS: This retrospective study included 173 patients (with 74 benign and 99 malignant lesions) who underwent mammography examination before neoadjuvant chemotherapy. Radiomic features were extracted from the mammography image of each patient. Several preprocessing methods, including centering and normalization, were used along with statistical analysis to reduce and select radiomic features. Four machine learning algorithms, namely, support vector machine, logistic regression, K-nearest neighbor, and Bayes classification, were applied to construct a predictive model. An independent testing data set was used to validate the prediction ability of the model. The classification performance was compared with the diagnostic predictions of two breast radiologists who had access to the same mammography cases.
RESULTS: A total of 51 radiomic features remained after the preprocessing. Logistic regression classification presented the best differentiation ability among the four regression models. The diagnostic accuracy, specificity, and sensitivity of the logistic regression model for the training data set were 0.978, 0.975, and 0.983, respectively. The diagnostic accuracy, specificity, and sensitivity for the testing data set were 0.886, 0.900, and 0.867, respectively. The accuracy, specificity, and sensitivity of the combined reading of the two radiologists were 0.772, 0.710, 0.862 in the training data set and 0.769, 0.695, 0.858 in the testing data set, respectively.
CONCLUSIONS: Mammography images could be captured and quantified by radiomics, which offers a good diagnostic ability for benign and malignant breast tumors and provides complementary information to radiologists.
引用
- Mao N, Yin P, Wang Q, et al. Added Value of Radiomics on Mammography for Breast Cancer Diagnosis: A Feasibility Study. J Am Coll Radiol. 2018. PMID: 30528092. doi:10.1016/j.jacr.2018.09.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。