通过微超声、彩色及脉冲波多普勒评估全身低灌注所致急性肾损伤大鼠模型
研究通过股动脉导管以1 mL/min抽血诱导大鼠出血性休克,使平均动脉压降至25-30 mmHg并维持60分钟,用Vevo 2100系统MS250探头(13-24 MHz)行微超声、彩色及脉冲波多普勒评估肾脏。结果示B模式仅见肾脏回声轻微改变,多普勒显示肾血流减少及阻力指数进行性显著变化,组织学证实60分钟低灌注导致肾脏缺血性改变。
要点
- 出血性休克大鼠模型通过股动脉以1 mL/min抽血使平均动脉压降至25-30 mmHg并维持60分钟。
- 低灌注1小时后B模式仅见肾脏回声轻微改变。
- 彩色及脉冲波多普勒显示肾血流减少,阻力指数较基线进行性显著变化。
核心结论
- 该实验研究结果鼓励使用所述模型通过严重低灌注研究急性肾缺血,组织学数据证实该模型能造成肾实质损伤。
研究设计与样本
- 动物实验研究,大鼠出血性休克模型,通过股动脉导管以1 mL/min抽血使平均动脉压降至25-30 mmHg并维持60分钟,使用Vevo 2100系统MS250探头(13-24 MHz)行微超声、彩色及脉冲波多普勒,并以组织学评估为参考。
关键影像表现/征象
- 低灌注1小时后B模式图像显示肾脏回声轻微改变。
- 彩色及脉冲波多普勒显示低灌注期间肾血流减少。
- 低灌注期间阻力指数较基线值进行性显著变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To create an animal model of acute renal ischemia induced by systemic hypoperfusion, controllable and reproducible to study, in real time, hemorrhagic shock changes with micro-imaging.
ANIMALS AND METHODS: Hemorrhagic shock was induced in rats activating a syringe pump setup to remove 1 mL/min of blood, through the femoral artery catheter. The withdrawal was continued until the mean arterial pressure (MAP) dropped to 25-30 mmHg. For the next 60 min, the MAP was maintained at a constant pressure value, by automatic pump infusion and withdrawal. Micro-ultrasound imaging was performed using the Vevo 2100 system with the MS250 transducer (13-24 MHz). Renal size, morphology and echogenicity were evaluated in B-mode. Renal blood flow was evaluated using color and PW-Doppler.
RESULTS: After 1 h of ischemia, B-mode images documented slight changes in kidney echogenicity. Color and PW-Doppler analysis showed a reduction in renal blood flow in kidneys during the hypoperfusion with a progressive and significant change from baseline values of resistive index (RI). At the histological evaluation, 60 min of hypoperfusion resulted in ischemic changes in the kidneys.
CONCLUSIONS: The results of this experimental study encourage the use of the described model to study acute renal ischemia trough severe hypoperfusion. The histological data confirmed that the model was able to produce injury in renal parenchyma. It can be used to assess acute ischemic damage not only in the kidney but also in other organs by using all available dedicated small animals imaging techniques.
引用
- Iacobellis F, Segreto T, Berritto D, et al. A rat model of acute kidney injury through systemic hypoperfusion evaluated by micro-US, color and PW-Doppler. Radiol Med. 2018. PMID: 30542911. doi:10.1007/s11547-018-0962-8