文献速递泌尿生殖MR

弥散峰度成像与弥散张量成像在区分良性组织、低级别与高级别Gleason分级前列腺癌中的表现

Performance of Diffusion Kurtosis Imaging Versus Diffusion Tensor Imaging in Discriminating Between Benign Tissue, Low and High Gleason Grade Prostate Cancer.
PubMed 文献 · Acad Radiol · 2018-12-11

研究纳入48例经活检证实为不同Gleason分级前列腺癌的患者,行3T DWI检查(b值0、500、1000、1500、2000、2500 s/mm²,6个梯度方向),比较DKI与DTI直方图参数区分良性组织、低级别与高级别前列腺癌的能力。结果显示除K、KFAp90和FA外,各参数均可显著区分前列腺癌与良性及瘤周组织;Kp90与Gleason分级相关性最高,区分低级别与高级别前列腺癌的AUC为0.84。作者认为DKI较DTI提供补充信息,对前列腺癌组织改变更敏感,区分低级别与高级别前列腺癌更准确。

要点

  • Kp90与Gleason分级相关性最高,区分低级别与高级别前列腺癌的AUC为0.84。
  • 除K、KFAp90和FA外,各弥散参数均可显著区分前列腺癌与良性及瘤周组织。
  • DKI较DTI对前列腺癌组织改变更敏感,区分低级别与高级别前列腺癌更准确。

核心结论

  • 与DTI相比,DKI提供关于前列腺癌组织的补充和额外信息,对前列腺癌所致改变更敏感,区分低级别与高级别前列腺癌更准确。

研究设计与样本

  • 纳入48例经活检证实为不同Gleason分级前列腺癌并签署书面知情同意的患者,行3T DWI检查,b值0、500、1000、1500、2000、2500 s/mm²,6个梯度方向,获取平均弥散率、FA、K、D和KFA图。

诊断标准与关键数值

  • Kp90区分低级别与高级别前列腺癌的AUC为0.84,与Gleason分级相关性最高;除K、KFAp90和FA外,各参数均可显著区分前列腺癌与良性及瘤周组织。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate the performance of diffusion kurtosis imaging (DKI) and diffusion tensor imaging (DTI) in discriminating benign tissue, low- and high-grade prostate adenocarcinoma (PCa).

MATERIALS AND METHODS: Forty-eight patients with biopsy-proven PCa of different Gleason grade (GG), who provided written informed consent, were enrolled. All subjects underwent 3T DWI examinations by using b values 0, 500, 1000, 1500, 2000, and 2500 s/mm2 and six gradient directions. Mean diffusivity, fractional anisotropy (FA), apparent kurtosis (K), apparent kurtosis-derived diffusivity (D), and proxy fractional kurtosis anisotropy (KFA) maps were obtained. Regions of interest were selected in PCa, in the contralateral benign zone, and in the peritumoral area. Histogram analysis was performed by measuring mean, 10th, 25th, and 90th (p90) percentile of the whole-lesion volume. Kruskal-Wallis test with Bonferroni correction was used to assess significant differences between different regions of interest. The correlation between diffusion metrics and GG and between DKI and DTI parameters was evaluated with Pearson's test. ROC curve analysis was carried out to analyze the ability of histogram variables to differentiate low- and high-GG PCa.

RESULTS: All metrics significantly discriminated PCa from benign and from peritumoral tissue (except for K, KFAp90, and FA). Kp90 showed the highest correlation with GG and the best diagnostic ability (area under the curve = 0.84) in discriminating low- from high-risk PCa.

CONCLUSION: Compared to DTI, DKI provides complementary and additional information about prostate cancer tissue, resulting more sensitive to PCa-derived modifications and more accurate in discriminating low- and high-risk PCa.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Di Trani MG, Nezzo M, Caporale AS, et al. Performance of Diffusion Kurtosis Imaging Versus Diffusion Tensor Imaging in Discriminating Between Benign Tissue, Low and High Gleason Grade Prostate Cancer. Acad Radiol. 2018. PMID: 30545680. doi:10.1016/j.acra.2018.11.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。