光谱探测器CT虚拟单能图像改善低密度肝脏病灶显示:3D打印体模概念验证与74例患者评估

Improved visualization of hypodense liver lesions in virtual monoenergetic images from spectral detector CT: Proof of concept in a 3D-printed phantom and evaluation in 74 patients.
PubMed 文献 · Eur J Radiol · 2018-11-03

本研究通过3D打印肝脏体模和74例回顾性患者资料,评估光谱探测器CT低keV虚拟单能图像(VMI_low)能否通过提高肝实质碘对比剂衰减来改善低或未强化病灶的显示。体模中VMI_low的CNR显著更高,囊性模拟病灶在常规图像CNR为6.4±0.8,VMI_40 keV下轻度低密度病灶模拟物CNR为5.8±0.9(p≤0.05);患者中囊性病灶常规图像CNR为4.4±1.2、转移灶VMI_40 keV为3.9±1.8(p≤0.05),定性分析提示VMI_40 keV有益(p≤0.05)。

要点

  • 利用低keV虚拟单能图像提高肝实质强化,可反向利用对比泛光效应改善低密度病灶显示。
  • 体模中VMI_low的CNR显著高于常规图像,轻度低密度病灶在VMI_40 keV下CNR接近囊性病灶在常规图像的CNR。
  • 患者中VMI_40 keV对低密度病灶显示的定性评估优于常规图像。

核心结论

  • 光谱探测器CT低keV虚拟单能图像通过反向利用对比泛光概念,可改善低密度局灶性肝脏病灶的可视化。

研究设计与样本

  • 回顾性研究,共纳入74例在光谱探测器CT上行增强检查的患者,病灶经MRI或随访证实为囊肿和/或低密度转移瘤;另设计3D打印肝脏体模,实质模拟物填充80/100/120 HU溶液,病灶模拟物填充0/15/40/60 HU溶液;重建40–200 keV虚拟单能图像及常规图像,由两名放射科医师独立评估图像质量。

诊断标准与关键数值

  • 体模中囊性模拟病灶在高衰减实质模拟物常规图像上CNR为6.4±0.8;VMI_40 keV下轻度低密度病灶模拟物在低衰减实质模拟物中CNR为5.8±0.9(p≤0.05)。患者中囊肿在常规图像CNR为4.4±1.2,转移灶在VMI_40 keV CNR为3.9±1.8(p≤0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The well-known boost of iodine associated-attenuation in low-keV virtual monoenergetic images (VMI_low) is frequently used to improve visualization of lesions and structures taking up contrast media. This study aimed to evaluate this concept in reverse. Hence to investigate if increased attenuation within the liver allows for improved visualization of little or not-enhancing lesions.

METHODS: A 3D-printed phantom mimicking the shape of a human liver exhibiting a lesion in its center was designed and printed. Both, parenchyma- and lesion-mimic were filled with different solutions exhibiting 80/100/120HU and 0/15/40/60HU, respectively. Further, a total of 74 contrast-enhanced studies performed on a spectral detector CT scanner (SDCT) were included in this retrospective study. Patients had MRI or follow-up proven cysts and/or hypodense metastases. VMI of 40-200 keV as well as conventional images (CI) were reconstructed. ROI were placed in lesion and parenchyma(-mimics) on CI and transferred to VMI. Signal- and contrast-to-noise ratio were calculated (S-/CNR). Further, two radiologists independently evaluated image quality. Data was statistically assessed using ANOVA or Wilcoxon-test.

RESULTS: In phantoms, S/CNR was significantly higher in VMI_low. The cyst-mimic in highly attenuating parenchyma-mimic on CI yielded a CNR of 6.4 ± 0.8; using VMI_40 keV, mildly hypodense lesion-mimic in poorly attenuating parenchyma-mimic exhibited a similar CNR (5.8 ± 0.9; p ≤ 0.05). The same tendency was observed in patients (cyst in CI/metastasis in VMI_40 keV: 4.4 ± 1.2/3.9 ± 1.8; p ≤ 0.05). Qualitative analysis indicated a benefit of VMI_40 keV (p ≤ 0.05).

CONCLUSIONS: VMI_low from SDCT allow for an improved visualization of hypodense focal liver lesions exploiting the concept of contrast blooming in reverse.

来源:Eur J Radiol,查看原文。版权归原作者所有。