钆塞酸增强MRI纹理分析在鉴别肝细胞腺瘤与局灶性结节性增生中的价值
本研究纳入40例患者51个肝细胞腺瘤和28例患者32个局灶性结节性增生,评估钆塞酸增强MRI纹理分析对两者的鉴别诊断效能。肝细胞腺瘤在T2加权成像、肝动脉期和肝胆期的偏度及肝胆期熵值分布与局灶性结节性增生有统计学差异,肝胆期偏度诊断肝细胞腺瘤的AUROC为0.869,阈值大于-0.06时敏感度72.5%、特异度90.6%。联合肝胆期低信号和纹理分析参数诊断肝细胞腺瘤的AUROC为0.979,正确预测96.4%的病灶。
要点
- 肝胆期偏度诊断肝细胞腺瘤的AUROC为0.869,阈值大于-0.06时敏感度72.5%、特异度90.6%;51个肝细胞腺瘤中6个(11.8%)在肝胆期无低信号。
- 联合肝胆期低信号和纹理分析参数诊断肝细胞腺瘤的AUROC为0.979,正确预测96.4%的病灶。
- 纹理分析可能对肝胆期无低信号的不典型肝细胞腺瘤的诊断有附加价值。
核心结论
- 纹理分析可能对肝胆期无低信号的不典型肝细胞腺瘤的诊断有附加价值。
研究设计与样本
- 研究纳入40例患者(39例女性、1例男性)的51个肝细胞腺瘤和28例患者(27例女性、1例男性)的32个局灶性结节性增生,所有病灶均经组织学证实并有术前钆塞酸增强MRI。两名阅片者评估定性MRI特征,采用T2加权快速自旋回波、肝动脉期和肝胆期序列进行纹理分析,纹理特征用商用软件(TexRAD)提取。
诊断标准与关键数值
- 肝细胞腺瘤与局灶性结节性增生在T2加权成像偏度、肝动脉期偏度、肝胆期偏度和肝胆期熵值上分布有统计学差异(P<0.001);肝胆期偏度AUROC最大(0.869;95%CI 0.777-0.933);肝胆期偏度大于-0.06诊断肝细胞腺瘤的敏感度72.5%、特异度90.6%;51个肝细胞腺瘤中6个(11.8%)在肝胆期无低信号;联合肝胆期低信号和统计学显著的纹理分析参数诊断肝细胞腺瘤的AUROC为0.979,正确预测96.4%的病灶。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The objective of our study was to assess the diagnostic performance of texture analysis (TA) on gadoxetic acid-enhanced MR images for differentiation of hepatocellular adenoma (HCA) from focal nodular hyperplasia (FNH).
MATERIALS AND METHODS: This study included 40 patients (39 women and one man) with 51 HCAs and 28 patients (27 women and one man) with 32 FNH lesions. All lesions were histologically proven with preoperative MRI performed with gadoxetic acid. Two readers reviewed all the imaging sequences to assess the qualitative MRI characteristics. The T2-weighted fast spin-echo, hepatic arterial phase (HAP), and hepatobiliary phase (HBP) sequences were used for TA. Textural features were extracted using commercially available software (TexRAD). The differences in distributions of TA parameters of FNHs and HCAs were assessed using the Mann-Whitney U test. Area under the ROC curve (AUROC) values were calculated for statistically significant features. A logistic regression analysis was conducted to explore the added value of TA. A p value < 0.002 was considered statistically significant after Bonferroni correction for multiple comparisons.
RESULTS: Multiple TA parameters showed a statistically different distribution in HCA and FNH including skewness on T2-weighted imaging, skewness on HAP imaging, skewness on HBP imaging, and entropy on HBP imaging (p < 0.001). Skewness on HBP imaging showed the largest AUROC (0.869; 95% CI, 0.777-0.933). A skewness value on HBP imaging of greater than -0.06 had a sensitivity of 72.5% and a specificity of 90.6% for the diagnosis of HCA. Six of 51 (11.8%) HCAs lacked hypointensity on HBP imaging. A binary logistic regression analysis including hypointensity on HBP imaging and the statistically significant TA parameters yielded an AUROC of 0.979 for the diagnosis of HCA and correctly predicted 96.4% of the lesions.
CONCLUSION: TA may be of added value for the diagnosis of atypical HCA presenting without hypointensity on HBP imaging.
引用
- Cannella R, Rangaswamy B, Minervini MI, et al. Value of Texture Analysis on Gadoxetic Acid-Enhanced MRI for Differentiating Hepatocellular Adenoma From Focal Nodular Hyperplasia. AJR Am J Roentgenol. 2018. PMID: 30557050. doi:10.2214/AJR.18.20182
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。