双能CT虚拟单色图像能否替代低kVp图像用于中小体型患者腹部增强CT

Can virtual monochromatic images from dual-energy CT replace low-kVp images for abdominal contrast-enhanced CT in small- and medium-sized patients?
PubMed 文献 · Eur Radiol · 2018-11-30

研究比较双能CT联合自动能谱成像协议选择(ASIS)与低kVp CT在腹部多期扫描中的图像质量和辐射剂量,每组60例,按BMI匹配。约55 keV和62 keV虚拟单色图像分别与80 kVp和100 kVp图像的CT值和对比度相似;50 keV虚拟单色图像整体图像质量相似或更高,辐射剂量较80 kVp CT增加10%,与100 kVp CT相似。

要点

  • 约55 keV和62 keV虚拟单色图像分别与80 kVp和100 kVp图像的CT值和对比度相似。
  • 50 keV虚拟单色图像相比匹配的低kVp图像提供更高CT值和图像噪声,对比度及整体图像质量相似或更高。
  • 双能CT联合ASIS辐射剂量较80 kVp CT增加10%,与100 kVp CT相似。

核心结论

  • 在中小体型患者中,双能CT联合ASIS的50 keV虚拟单色图像相比匹配的低kVp CT提供相似或更高的整体图像质量,辐射剂量无或极小增加。

研究设计与样本

  • 四组各60例患者分别接受低kVp CT(A组:80 kVp/300 mg I/kg,BMI≤23.9 kg/m2;C组:100 kVp/400 mg I/kg,BMI 24–28.9 kg/m2)或双能CT联合ASIS并生成40–60 keV虚拟单色图像(B组和D组),按年龄、性别、BMI、横截面积和对比剂剂量匹配;9例因技术失败被排除;在1.25 mm重建图像上比较匹配协议(A与B或C与D)的CT值、图像噪声、对比噪声比和主观图像质量。

诊断标准与关键数值

  • 约55 keV虚拟单色图像的CT值和对比度与80 kVp CT图像相似。
  • 约62 keV虚拟单色图像的CT值和对比度与100 kVp CT图像相似。
  • 50 keV虚拟单色图像相比匹配的低kVp图像CT值和图像噪声更高,对比度和整体图像质量相似或更高。

临床应用与阅片要点

  • 双能CT联合ASIS生成的50 keV虚拟单色图像在中小体型患者腹部增强CT中可能替代100 kVp CT用于常规临床扫描。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the image quality and radiation dose of dual-energy computed tomography (DECT) with automatic spectral imaging protocol selection (ASIS) compared with those of low-kVp CT in abdominal multiphase CT.

METHODS: Four groups of 60 patients each underwent abdominal scans with low-kVp CT (A, 80 kVp/300 mg I/kg, body mass index [BMI] ≤ 23.9 kg/m2; C, 100 kVp/400 mg I/kg, BMI ranging from 24 to 28.9 kg/m2) or DECT with ASIS, and the 40- to 60-keV virtual monochromatic images (VMIs) generated (B and D) were matched by age, gender, BMI, cross-sectional area, and contrast agent dose; 9 patients were excluded due to technical failures. The CT number, image noise, contrast-to-noise ratio, and subjective image quality were compared between the matched protocols (A and B or C and D) on 1.25-mm reconstructed images.

RESULTS: VMIs at approximately 55 keV and 62 keV had CT numbers and contrast similar to those of 80-kVp and 100-kVp CT images, respectively. Compared to matched low-kVp images, VMIs at 50 keV provided a higher CT number and image noise and a similar or higher contrast and overall image quality. The radiation dose for DECT was higher than that of 80-kVp CT (increased by 10%), but was similar to that of 100-kVp CT.

CONCLUSION: Compared to matched low-kVp CT, VMIs at 50 keV in DECT with ASIS provided similar or higher overall image quality, with no or minimal dose penalty in small- and medium-sized patients.

KEY POINTS: • Virtual monochromatic images at approximately 55 keV and 62 keV have CT numbers and contrast similar to those of 80-kVp and 100-kVp CT images, respectively, with a given noise index. • The radiation dose in dual-energy CT with automatic spectral imaging protocol selection was slightly higher than that of 80-kVp CT (increased by 10%) but was similar to that of 100-kVp CT. • Dual-energy CT may be able to replace l00-kVp CT for routine clinical abdominal contrast-enhanced CT scans.