文献速递腹部CT

腹部单源双能CT单能图像的最佳窗宽窗位设置

Optimal window settings in single-source dual-energy computed tomography of the abdomen.
PubMed 文献 · Eur J Radiol · 2018-10-23

本研究纳入200例腹部增强双能CT患者,由两名放射科医师以65 keV图像窗位40 HU、窗宽350 HU为参考,调整并记录40至75 keV共8个能级的窗位与窗宽,剔除上下5%数据后取中位数得到各能级最佳窗宽窗位;另在7例患者的23个肝转移瘤中比较各能级对比噪声比,65 keV图像对比噪声比最佳(P < 0.001)。

要点

  • 腹部双能CT单能图像最佳窗位随能级降低而升高,40 keV为140 HU,65 keV为40 HU,75 keV为20 HU。
  • 最佳窗宽同样随能级降低而增大,40 keV为680 HU,65 keV为350 HU,75 keV为300 HU。
  • 23个肝转移瘤中65 keV图像肿瘤-肝脏对比噪声比最佳(P < 0.001)。

核心结论

  • 研究明确了腹部双能CT各预设单能图像(40至75 keV)对应的最佳窗位与窗宽,其中65 keV图像的肿瘤-肝脏对比噪声比最佳(P < 0.001)。

研究设计与样本

  • 连续纳入200例术后筛查肿瘤转移和/或复发的患者行腹部增强双能CT,两名独立放射科医师审阅门静脉期40、45、50、55、60、65、70、75 keV共8个能级的单能图像。

诊断标准与关键数值

  • 各能级最佳窗位与窗宽:40 keV为140和680 HU,45 keV为110和570 HU,50 keV为90和490 HU,55 keV为70和440 HU,60 keV为60和390 HU,65 keV为40和350 HU,70 keV为30和320 HU,75 keV为20和300 HU。
  • 以65 keV图像窗位40 HU、窗宽350 HU为参考设置,剔除上下各5%数据后取中位数并取整得到各能级最佳窗宽窗位。
  • 7例患者共23个肝转移瘤中,65 keV图像的肿瘤-肝脏对比噪声比最佳(P < 0.001)。

临床应用与阅片要点

  • 阅片时可参照本研究给出的各能级最佳窗位与窗宽预设腹部双能CT单能图像,能级越低窗位与窗宽越大。
  • 评估肝转移瘤时65 keV图像可获得最佳的肿瘤-肝脏对比噪声比(P < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the optimal window settings for monochromatic images with various energy levels in single-source dual-energy computed tomography (DECT) of the abdomen.

MATERIALS AND METHODS: Two hundred consecutive patients underwent contrast-enhanced DECT to screen tumor metastases and/or recurrences after surgery for malignant tumors. Two independent radiologists reviewed eight energy levels (40, 45, 50, 55, 60, 65, 70, and 75 kilo-electron volts [keV]) of the portal venous phase monochromatic images. For each keV image, the radiologists adjusted the window level (WL) and width (WW) using settings of 40 HU of WL and 350 HU of WW on 65 keV images as a reference and recorded these values. After removing the top and bottom 5% of the data, the optimal WL and WW in each energy levels were obtained by rounding the median values. In 7 of 200 patients with a total of 23 liver metastases, the tumor-to-liver contrast-to-noise ratio (CNR) was calculated and compared among the energy levels.

RESULTS: The optimal WLs and WWs at each energy level were as follows: 40 keV, 140 and 680 HU; 45 keV, 110 and 570 HU; 50 keV, 90 and 490 HU; 55 keV, 70 and 440 HU; 60 keV, 60 and 390 HU; 65 keV, 40 and 350 HU; 70 keV, 30 and 320 HU; and 75 keV, and 20 and 300 HU. The best CNR was obtained using 65 keV images (P < 0.001).

CONCLUSION: We clarified the optimal WL and WW available for the preset window settings in abdominal DECT.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Noda Y, Goshima S, Kozaka K, et al. Optimal window settings in single-source dual-energy computed tomography of the abdomen. Eur J Radiol. 2018. PMID: 30527306. doi:10.1016/j.ejrad.2018.10.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。