文献速递心血管CT

基于模型的迭代重建算法评估冠状动脉的诊断效能:与标准混合迭代重建算法相比的剂量降低和图像质量

Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality.
PubMed 文献 · Radiol Med · 2018-12-11

前瞻性纳入98例疑诊冠心病患者,52例采用256-MDCT低剂量冠状动脉CTA(80 kV、自动mAs、60 mL对比剂350 mgI/mL、前瞻性ECG触发)联合IMR重建,46例采用标准方案(100 kV、自动mAs、70 mL对比剂400 mgI/mL、iDose4)。IMR组mAs和辐射剂量显著降低(DLP降低38%),冠状动脉平均CT值更高、SNR和CNR更高,主观图像质量两组无显著差异。

要点

  • IMR低剂量cCTA较iDose4标准方案DLP降低38%(91.7 vs 148.6 mGy cm)。
  • IMR组LAD平均CT值491 HU,高于iDose4组443 HU(p=0.03)。
  • 两组主观图像质量无显著差异(p=0.23)。

核心结论

  • 低剂量cCTA联合IMR重建可正确评估冠状动脉病变,提供高质量图像,且较标准cCTA方案显著降低辐射剂量38%。

研究设计与样本

  • 前瞻性研究,共98例有冠状动脉CT检查指征的患者;研究组52例行256-MDCT低剂量cCTA(80 kV、自动mAs、60 mL对比剂350 mgI/mL、前瞻性ECG触发)联合IMR重建,对照组46例行256-MDCT标准前瞻性ECG门控方案(100 kV、自动mAs、70 mL对比剂400 mgI/mL)联合iDose4重建;由两名放射科医师主观评价图像质量,并测量客观图像质量指标(衰减值、SD、SNR、CNR),辐射剂量以DLP、CTDIvol和ED量化。

关键影像表现/征象

  • IMR组平均mAs为167 ± 62 mAs,显著低于iDose4组的278 ± 55 mAs(p < 0.001)。
  • IMR组LAD平均密度为491 HU,高于iDose4组的443 HU(p = 0.03)。
  • IMR组SNR和CNR显著更高,归因于更低的噪声水平。
  • 定性分析两组间无显著差异(p = 0.23)。

诊断标准与关键数值

  • 辐射剂量以DLP、CTDIvol和ED量化,IMR组DLP为91.7 ± 26 mGy cm,iDose4组为148.6 ± 35 mGy cm,IMR组降低38%(p < 0.001)。
  • 客观图像质量指标包括衰减值、SD、SNR和CNR。

临床应用与阅片要点

  • 低剂量cCTA联合IMR重建可在显著降低辐射剂量的同时保持主观图像质量。
  • IMR组冠状动脉平均CT值更高,SNR和CNR更高,噪声水平更低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the image quality and radiation dose exposure of low-dose coronary CTA (cCTA) study, reconstructed with the new model-based iterative reconstruction algorithm (IMR), compared with standard hybrid-iterative reconstruction (iDose4) cCTA in patients with suspected coronary artery disease.

MATERIALS AND METHODS: Ninety-eight patients with an indication for coronary CT study were prospectively enrolled. Fifty-two patients (study group) underwent 256-MDCT low-dose cCTA (80 kV; automated-mAs; 60 mL of CM, 350 mgL/mL) with prospective ECG-triggering acquisition and IMR. A control group of 46 patients underwent 256-MDCT standard prospective ECG-gated protocol (100 kV; automated-mAs; 70 mL of CM, 400 mgL/mL; iDose4). Subjective and objective image quality (attenuation value, SD, SNR and CNR) were evaluated by two radiologists subjectively. Radiation dose exposure was quantified as DLP, CTDIvol and ED.

RESULTS: Mean values of mAs were significantly lower for IMR-cCTA (167 ± 62 mAs) compared to iDose-cCTA (278 ± 55 mAs), p < 0.001. With a significant reduction of 38% in radiation dose exposure (DLP: IMR-cCTA 91.7 ± 26 mGy cm vs. iDose-cCTA 148.6 ± 35 mGy cm; p value < 0.001), despite the use of different CM, we found higher mean attenuation values of the coronary arteries in IMR group compared to iDose4 (mean density in LAD: 491HU IMR-cCTA vs. 443HU iDose-cCTA; p = 0.03). We observed a significant higher value of SNR and CNR in study group due to a lower noise level. Qualitative analysis did not reveal any significant differences between the two groups (p = 0.23).

CONCLUSIONS: Low-dose cCTA study combined with IMR reconstruction allows to correctly evaluate coronary arteries disease, offering high-quality images and significant radiation dose exposure reduction (38%), as compared to standard cCTA protocol.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Ippolito D, Riva L, Talei Franzesi CR, et al. Diagnostic efficacy of model-based iterative reconstruction algorithm in an assessment of coronary artery in comparison with standard hybrid-Iterative reconstruction algorithm: dose reduction and image quality. Radiol Med. 2018. PMID: 30539411. doi:10.1007/s11547-018-0964-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。