文献速递胸部CT

应用CT纹理分析确定低剂量CT筛查中检出的亚实性结节的预后价值

Applying CT texture analysis to determine the prognostic value of subsolid nodules detected during low-dose CT screening.
PubMed 文献 · Clin Radiol · 2018-11-27

回顾性分析86例低剂量CT筛查者的89个亚实性结节(42个纯磨玻璃结节、47个部分实性结节),评估CT纹理参数预测恶性与生长的价值。结果显示癌组熵值显著高于生长组和非生长组,能量显著低于其他组;均匀性与体积倍增时间呈正相关。

要点

  • 癌组亚实性结节的熵值显著高于生长组和非生长组,能量显著低于其他组。
  • 均匀性与体积倍增时间呈良好正相关(p=0.022)。
  • 均匀性可能用于预测基线纯磨玻璃结节的生长概率,以给予更多关注。

核心结论

  • 不同CT纹理参数对低剂量CT筛查检出的亚实性结节显示出良好预测价值:恶性肺结节与其他结节的熵值和能量差异可作为预测亚实性结节恶性的有用定量指标;均匀性可用于预测基线纯磨玻璃结节的生长概率,从而给予更多关注,使随访和治疗方案更有针对性。

研究设计与样本

  • 回顾性研究,纳入86例低剂量CT筛查参与者共89个亚实性结节,包括42个纯磨玻璃结节和47个部分实性结节;其中28个结节经组织病理学诊断为肺癌,61个结节来自至少接受两次低剂量CT检查的参与者;所有结节分为癌组、生长组和非生长组;评估结节大小、体积、衰减、体积倍增时间和纹理参数(均值、均匀性、熵和能量)。

关键影像表现/征象

  • 纯磨玻璃结节中,癌组熵值显著高于生长组(p=0.009)和非生长组(p=0.001)。
  • 部分实性结节中,癌组熵值显著高于生长组(p=0.012)和非生长组(p=0.004)。
  • 纯磨玻璃结节中,癌组能量显著低于生长组(p=0.043)和非生长组(p=0.021)。
  • 部分实性结节中,癌组能量显著低于生长组(p=0.001)和非生长组(p=0.002)。
  • 均匀性与体积倍增时间呈良好正相关(p=0.022)。

诊断标准与关键数值

  • 癌组与非癌组的纹理参数差异:纯磨玻璃结节熵值p=0.009(vs生长组)、p=0.001(vs非生长组);部分实性结节熵值p=0.012(vs生长组)、p=0.004(vs非生长组)。
  • 纯磨玻璃结节能量p=0.043(vs生长组)、p=0.021(vs非生长组);部分实性结节能量p=0.001(vs生长组)、p=0.002(vs非生长组)。
  • 均匀性与体积倍增时间正相关(p=0.022)。

临床应用与阅片要点

  • 熵值和能量差异可作为预测亚实性结节恶性的定量指标,辅助鉴别恶性肺结节与其他结节。
  • 均匀性可用于预测基线纯磨玻璃结节的生长概率,对均匀性较高的结节给予更多关注。
  • 纹理分析结果有助于使随访和治疗方案更有针对性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To analyse subsolid nodules (SSNs) detected during low-dose (LD) computed tomography (CT) screening and investigated whether CT texture analysis parameters can predict the malignancy and growth trends of GGNs.

MATERIALS AND METHODS: In this retrospective study, 89 SSNs were detected in 86 LDCT screening participants, including 42 pure ground-glass nodules (GGNs) and 47 part-solid GGNs. In these participants, 28 SSNs were diagnosed as lung cancer at histopathology, and 61 SSNs from participants who underwent at least two LDCT imaging studies. All nodules were divided into three groups: cancer group, growth group, and non-growth group. The nodule size, volume, attenuation, volume doubling time (VDT), and texture parameters (mean value, uniformity, entropy and energy) were assessed, respectively.

RESULTS: The entropy of the cancer group was significantly higher than that of the growth and non-growth groups (pure GGNs: p=0.009, 0.001; part-solid GGNs: p=0.012, 0.004). The energy of the cancer group was significantly lower than that of the other groups (pure GGNs: p=0.043, 0.021; part-solid GGNs: p=0.001, 0.002). A good positive correlation was found between uniformity and VDT (p=0.022).

CONCLUSION: Different CT texture parameters show good predictive value for SSNs detected at LDCT screening: the entropy and energy differences between malignant pulmonary nodules and others could be a helpful quantitative index to predict the malignancy of SSNs. Uniformity could be used to predict the growth probability of pure GGNs at baseline to pay more attention to these nodules. Moreover, the follow-up and treatment plan could be more targeted.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Sun Q, Huang Y, Wang J, et al. Applying CT texture analysis to determine the prognostic value of subsolid nodules detected during low-dose CT screening. Clin Radiol. 2018. PMID: 30501892. doi:10.1016/j.crad.2018.07.103

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。