三维超短回波时间与零回波时间序列肺成像的比较:初步研究
纳入20例患者,在常规肺MR中同时采集自由呼吸3D超短回波时间(UTE)与零回波时间(ZTE)序列,比较图像质量及亚厘米结节检出。ZTE的肺实质信噪比及支气管、小动脉的信噪比和对比噪声比均更高,对亚厘米结节的诊断准确率更高,扫描时间更短(131秒 vs 467秒)。
要点
- ZTE序列图像信噪比与对比噪声比优于UTE,扫描时间更短(131秒 vs 467秒)
- ZTE对亚厘米结节的诊断准确率高于UTE(阅片者1 AUC 0.972 vs 0.885;阅片者2 AUC 0.946 vs 0.855)
- 在常规肺MR中增加ZTE序列作为补充序列是可行的
核心结论
- 在常规肺MR中增加ZTE序列是可行的;与UTE相比,ZTE能以更短时间提供高分辨率肺结构信息,信噪比和对比噪声比更优。
研究设计与样本
- 经机构审查委员会批准的初步研究,20例患者在日常肺MR中同时接受UTE和ZTE序列检查,比较主观图像质量、肺实质信号、肺内结构及亚厘米结节的检出。
关键影像表现/征象
- ZTE肺实质信号的信噪比显著高于UTE(p < 0.05)
- ZTE外周支气管和小肺动脉的信噪比和对比噪声比均显著高于UTE(均p < 0.05)
- 两名独立放射科医生对正常结构显示和整体可接受性的主观图像质量评价ZTE优于UTE(p < 0.05)
- ZTE图像采集时声学噪声更小
诊断标准与关键数值
- 亚厘米结节的诊断准确率ZTE高于UTE:阅片者1 AUC 0.972(p = 0.044)vs 0.885;阅片者2 AUC 0.946(p = 0.045)vs 0.855
- 平均扫描时间ZTE 131秒(125–141秒)vs UTE 467秒(453–508秒)
临床应用与阅片要点
- 可将ZTE作为常规肺MR的补充序列,以较短扫描时间获得高分辨率肺结构信息
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the feasibility of using high-resolution volumetric zero echo time (ZTE) sequence in routine lung magnetic resonance imaging (MRI) and compare free breathing 3D ultrashort echo time (UTE) and ZTE lung MRI in terms of image quality and small-nodule detection.
MATERIALS AND METHODS: Our Institutional Review Board approved this study. Twenty patients underwent both UTE and ZTE sequences during routine lung MR. UTE and ZTE images were compared in terms of subjective image quality and detection of lung parenchymal signal, intrapulmonary structures, and sub-centimeter nodules. Differences between the two sequences were compared through statistical analysis.
RESULTS: Lung parenchyma showed significantly (p < 0.05) higher signal-to-noise ratio (SNR) in ZTE than in UTE. The SNR and contrast-to-noise ratio (CNR) of peripheral bronchus and small pulmonary arteries were significantly (all p < 0.05) higher in ZTE. Subjective image quality evaluated by two independent radiologists in terms of depicting normal structures and overall acceptability was superior in ZTE (p < 0.05). The diagnostic accuracy for sub-centimeter nodules was significantly higher for ZTE (reader 1: AUC, 0.972; p = 0.044; reader 2: AUC, 0.946; p = 0.045) than that for UTE (reader 1: AUC, 0.885; reader 2: AUC, 0.855). Mean scan time was 131 s (125-141 s) in ZTE and 467 s (453-508 s) in UTE. ZTE images were obtained with less acoustic noise.
CONCLUSION: Implementing ZTE as an additional sequence in routine lung MR is feasible. ZTE can provide high-resolution pulmonary structural information with better SNR and CNR using shorter time than UTE.
KEY POINTS: • Both UTE and ZTE techniques use very short TEs to capture signals from very short T2/T2* tissues. • ZTE is superior in capturing lung parenchymal signal than UTE. • ZTE provides high-resolution structural information with better SNR and CNR for normal intrapulmonary structures and small nodules using shorter scan time than UTE.
引用
- Bae K, Jeon KN, Hwang MJ, et al. Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study. Eur Radiol. 2018. PMID: 30547204. doi:10.1007/s00330-018-5889-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。