使用超极化氙-129磁共振定量吸烟者早期肺疾病
本研究采用超极化氙-129磁共振波谱测量功能性肺泡壁厚度及气体表观扩散系数,比较16例吸烟相关慢阻肺患者、9例临床健康吸烟者及10例健康从不吸烟者。结果示健康从不吸烟者隔壁厚度随年龄增加0.04 μm/年,年龄校正隔壁厚度与一氧化碳弥散量相关(R²=0.56),健康者8.8 μm vs 慢阻肺12.3 μm(p<0.001),且是唯一能区分健康者与健康吸烟者的指标(8.8 μm vs 10.6 μm;p<0.006)。
要点
- 超极化氙-129 MR测得的功能性肺泡壁厚度可区分健康者与健康吸烟者。
- 健康者隔壁厚度8.8 μm vs 健康吸烟者10.6 μm(p<0.006)。
- 健康者隔壁厚度8.8 μm vs 慢阻肺12.3 μm(p<0.001)。
核心结论
- 超极化氙-129 MR评估的功能性肺泡壁厚度可区分健康者与健康吸烟者,可能成为早期肺疾病的有力新指标。
研究设计与样本
- 研究纳入16例吸烟相关慢阻肺患者、9例临床健康吸烟者及10例健康从不吸烟者,均年龄匹配并接受常规肺功能检查,另加入11组年轻健康从不吸烟者数据以确定隔壁厚度测量的年龄依赖性。
关键影像表现/征象
- 健康从不吸烟者隔壁厚度随年龄增加0.04 μm/年。
- 健康吸烟者肺功能检查正常,与从不吸烟者无显著差异。
- 年龄校正隔壁厚度与一氧化碳弥散量相关(R²=0.56)。
诊断标准与关键数值
- 健康者隔壁厚度8.8 μm vs 慢阻肺患者12.3 μm(p<0.001)。
- 健康者隔壁厚度8.8 μm vs 健康吸烟者10.6 μm(p<0.006)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Hyperpolarized xenon-129 magnetic resonance (MR) provides sensitive tools that may detect early stages of lung disease in smokers before it has progressed to chronic obstructive pulmonary disease (COPD) apparent to conventional spirometric measures. We hypothesized that the functional alveolar wall thickness as assessed by hyperpolarized xenon-129 MR spectroscopy would be elevated in clinically healthy smokers before xenon MR diffusion measurements would indicate emphysematous tissue destruction.
MATERIALS AND METHODS: Using hyperpolarized xenon-129 MR we measured the functional septal wall thickness and apparent diffusion coefficient of the gas phase in 16 subjects with smoking-related COPD, 9 clinically healthy current or former smokers, and 10 healthy never smokers. All subjects were age-matched and characterized by conventional pulmonary function tests. A total of 11 data sets from younger healthy never smokers were added to determine the age dependence of the septal wall thickness measurements.
RESULTS: In healthy never smokers the septal wall thickness increased by 0.04 μm per year of age. The healthy smoker cohort exhibited normal pulmonary function test measures that did not significantly differ from the never-smoker cohort. The age-corrected septal wall thickness correlated well with diffusion capacity for carbon monoxide (R2 = 0.56) and showed a highly significant difference between healthy subjects and COPD patients (8.8 μm vs 12.3 μm; p < 0.001), but was the only measure that actually discriminated healthy subjects from healthy smokers (8.8 μm vs 10.6 μm; p < 0.006).
CONCLUSION: Functional alveolar wall thickness assessed by hyperpolarized xenon-129 MR allows discrimination between healthy subjects and healthy smokers and could become a powerful new measure of early-stage lung disease.
引用
- Ruppert K, Qing K, Patrie JT, et al. Using Hyperpolarized Xenon-129 MRI to Quantify Early-Stage Lung Disease in Smokers. Acad Radiol. 2018. PMID: 30522808. doi:10.1016/j.acra.2018.11.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。