头颈部肿瘤涡轮自旋回波与平面回波扩散加权MR成像的图像质量与ADC评估
研究比较口面部涡轮自旋回波扩散加权成像(TSE-DWI)与平面回波扩散加权成像(EPI-DWI)的畸变率、信噪比和对比噪声比,并在143个口面部病变中评估TSE-DWI所得表观扩散系数(ADC)的鉴别诊断价值。TSE-DWI畸变率显著更低、信噪比和对比噪声比更高;良恶性鉴别曲线下面积为0.80,ADC截断值1.29×10⁻³ mm²/s。
要点
- TSE-DWI较EPI-DWI畸变率显著更低,信噪比和对比噪声比更高。
- 口面部病变良恶性鉴别ADC截断值1.29×10⁻³ mm²/s,曲线下面积0.80。
- 鳞状细胞癌与其他恶性肿瘤的ADC差异无统计学意义(p=0.877)。
核心结论
- TSE-DWI的图像质量优于EPI-DWI,在口面部区域获得ADC的可能性高,该值被认为有助于口面部病变的鉴别诊断。
研究设计与样本
- 研究分两部分:第一部分在42例中比较TSE-DWI与EPI-DWI的畸变率、信噪比和对比噪声比,其中38例纳入分析;第二部分在143个病变中评估TSE-DWI所得ADC,其中114例(79.3%)成功分析。
诊断标准与关键数值
- 良恶性鉴别曲线下面积为0.80,ADC截断值1.29×10⁻³ mm²/s;病变分为囊肿、良性肿瘤、鳞状细胞癌、恶性淋巴瘤和其他恶性肿瘤,除鳞状细胞癌与其他恶性肿瘤外(p=0.877),其余各对病变间差异均有统计学意义(p<0.05)。
临床应用与阅片要点
- TSE-DWI畸变率显著更低(p<0.05)、信噪比和对比噪声比更高(p<0.05),口面部病变可借助其ADC值辅助鉴别诊断。
局限性
- 第一部分42例中仅38例纳入分析。
- 第二部分143个病变中仅114例(79.3%)成功分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI for the differential diagnosis of orofacial lesions.
MATERIALS AND METHODS: The DR, SNR, and CNR of both sequences were compared in 42 cases. Then, the apparent diffusion coefficient (ADC) of various orofacial lesions obtained by TSE-DWI was investigated in 143 lesions.
RESULTS: In the first study, 38 of 42 cases were analyzed. TSE-DWI showed a significantly lower DR (p < 0.05) and higher SNR and CNR than EPI-DWI (p < 0.05), indicating the superiority of TSE-DWI. In the second study, 114 cases (79.3%) were successfully analyzed. When lesions were divided into cysts, benign tumors, squamous cell carcinoma, malignant lymphoma, and other malignant tumors (OT), significant differences were observed in all pairs of lesions (p < 0.05) except squamous cell carcinoma and OT (p = 0.877). The area under the curve for distinguishing benign from malignant tumors was 0.80 with a cutoff ADC of 1.29 × 10-3 mm²/s.
CONCLUSION: TSE-DWI produced better quality images than EPI-DWI. TSE-DWI yields the high possibility of obtaining ADC in the orofacial region, and this value was considered useful for the differential diagnosis of orofacial lesions.
引用
- Panyarak W, Chikui T, Yamashita Y, et al. Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck. Acad Radiol. 2018. PMID: 30528753. doi:10.1016/j.acra.2018.11.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。