文献速递头颈神经CTMR

采用区域探测器CT的骨减影碘成像评估鼻咽癌颅底侵犯

Bone Subtraction Iodine Imaging Using Area Detector CT for Evaluation of Skull Base Invasion by Nasopharyngeal Carcinoma.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-12-06

回顾性纳入44例鼻咽癌分期患者,比较常规CT单独或联合区域探测器CT骨减影碘成像评估颅底侵犯的诊断效能,以MR与CT联合阅片为参考标准。联合骨减影碘成像较常规CT单独提高了敏感度(92.9% vs 78.6%,P=.02)和特异度(95.6% vs 86.1%,P=.01),AUC由0.90升至0.98(P<.001)。

要点

  • 骨减影碘成像联合常规CT评估颅底侵犯的敏感度92.9%、特异度95.6%,均高于常规CT单独。
  • 联合方案的AUC为0.98,显著大于常规CT单独的0.90(P<.001)。
  • 参考标准为神经放射学专家联合阅MR与CT图像,26例(59%)在84个部位显示颅底侵犯。

核心结论

  • 常规CT联合骨减影碘成像的诊断准确率较常规CT单独更接近CT联合MR的准确率。

研究设计与样本

  • 回顾性研究,纳入2012年4月至2017年11月间44例连续鼻咽癌分期患者,均行320排区域探测器CT增强扫描和增强MR检查;骨减影碘图像通过高分辨率可变形配准算法减影增强前后容积扫描生成;由两名盲法观察者评估蝶骨体、斜坡、双侧翼突根及岩骨多个部位的颅底侵犯;以经验丰富的神经放射学专家阅MR与CT图像为参考标准。

关键影像表现/征象

  • 常规CT联合骨减影碘成像评估颅底侵犯的敏感度为92.9%,常规CT单独为78.6%(P=.02)。
  • 联合方案的AUC为0.98,常规CT单独为0.90,差异有统计学意义(P<.001)。

诊断标准与关键数值

  • 常规CT联合骨减影碘成像评估颅底侵犯:敏感度92.9%、特异度95.6%、AUC 0.98。
  • 常规CT单独评估颅底侵犯:敏感度78.6%、特异度86.1%、AUC 0.90。
  • 参考标准中26例(59%)患者共84个部位显示颅底侵犯。

临床应用与阅片要点

  • 骨减影碘成像可作为常规CT的补充,用于鼻咽癌颅底侵犯评估。
  • 联合方案较常规CT单独更接近CT联合MR的准确率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Conventional CT has generally lower detectability of bone marrow invasion than MR imaging due to lower tissue contrast. The purpose of this study was to compare the diagnostic performance of conventional CT alone or in combination with bone subtraction iodine imaging using area detector CT for the evaluation of skull base invasion in patients with nasopharyngeal carcinoma.

MATERIALS AND METHODS: Forty-four consecutive patients who underwent contrast-enhanced CT using 320-row area detector CT and contrast-enhanced MR imaging for nasopharyngeal carcinoma staging between April 2012 and November 2017 were enrolled in this retrospective study. Bone subtraction iodine images were generated by subtracting pre- and postcontrast volume scans using a high-resolution deformable registration algorithm. Two blinded observers evaluated skull base invasion at multiple sites (sphenoid body, clivus, bilateral base of the pterygoid process, and petrous bone) using conventional CT images alone or in combination with bone subtraction iodine images. Examination of MR and CT images by an experienced neuroradiologist was the reference standard for evaluating sensitivity, specificity, and area under the receiver operating characteristic curve.

RESULTS: Twenty-six patients (59%) showed skull base invasion at 84 sites on the reference standard. Conventional CT plus bone subtraction iodine images showed higher sensitivity (92.9% versus 78.6%, P = .02) and specificity (95.6% versus 86.1%, P = .01) than conventional CT images alone for evaluating skull base invasion. The area under the receiver operating characteristic curve for conventional CT plus bone subtraction iodine (0.98) was significantly larger (P < .001) than the area under the receiver operating characteristic curve for conventional CT alone (0.90).

CONCLUSIONS: Conventional CT plus bone subtraction iodine performs more closely to the accuracy of combining CT and MR imaging compared with conventional CT alone.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Hiyama T, Kuno H, Sekiya K, et al. Bone Subtraction Iodine Imaging Using Area Detector CT for Evaluation of Skull Base Invasion by Nasopharyngeal Carcinoma. AJNR Am J Neuroradiol. 2018. PMID: 30523140. doi:10.3174/ajnr.A5906

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。