文献速递神经儿科影像MR

胎儿手术时代开放性脊柱闭合不全中基于MR成像的后颅窝与脑干测量的可靠性

Reliability of MR Imaging-Based Posterior Fossa and Brain Stem Measurements in Open Spinal Dysraphism in the Era of Fetal Surgery.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-12-27

回顾性评估349例次胎儿MR检查(274例正常对照、52例开放性脊柱闭合不全胎儿,其中23例接受产前修复并有术后早期MR),评估脑干和后颅窝测量的可靠性;小脑横径、小脑疝出水平、斜坡-上枕角、后颅窝横径、后颅窝面积和脑室宽度观察者内和观察者间可靠性可接受(ICC>0.5),在开放性脊柱闭合不全胎儿中与健康胎儿显著不同(均P<.0001),且胎儿术后1周内显著变化并趋向正常。

要点

  • 后颅窝及小脑相关测量在开放性脊柱闭合不全胎儿中观察者内和观察者间可靠性可接受(ICC>0.5)。
  • 开放性脊柱闭合不全胎儿上述测量与健康胎儿显著不同(均P<.0001)。
  • 胎儿术后1周内上述测量显著变化并趋向正常,以斜坡-上枕角和小脑疝出水平最明显。

核心结论

  • 开放性脊柱闭合不全胎儿中脑干测量在观察者间变异较大,但后颅窝相关测量可可靠评估且与正常显著不同;胎儿手术后1周内这些偏离正常值的测量显著变化。

研究设计与样本

  • 回顾性评估349例次MR检查,包括274例正常对照和52例开放性脊柱闭合不全胎儿,其中23例接受产前修复并加做术后早期MR。

关键影像表现/征象

  • 开放性脊柱闭合不全胎儿后颅窝及小脑相关测量与健康胎儿显著不同(均P<.0001)。
  • 胎儿术后1周内上述测量显著变化并趋向正常(P值范围 .01至<.0001)。
  • 斜坡-上枕角从65.9±12.5°变为76.6±10.9°(P<.0001),小脑疝出水平从-9.9±4.2 mm变为-0.7±5.2 mm(P<.0001)。
  • 脑干测量在开放性脊柱闭合不全胎儿中观察者间变异较大。

诊断标准与关键数值

  • 小脑横径、小脑疝出水平、斜坡-上枕角、后颅窝横径、后颅窝面积和脑室宽度的观察者内和观察者间可靠性可接受(ICC>0.5)。

临床应用与阅片要点

  • 后颅窝相关测量(小脑横径、小脑疝出水平、斜坡-上枕角、后颅窝横径、后颅窝面积和脑室宽度)可可靠用于评估开放性脊柱闭合不全胎儿并与正常对照区分。
  • 脑干测量在开放性脊柱闭合不全胎儿中观察者间变异较大,解读时需谨慎。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Fetal MR imaging is part of the comprehensive prenatal assessment of fetuses with open spinal dysraphism. We aimed to assess the reliability of brain stem and posterior fossa measurements; use the reliable measurements to characterize fetuses with open spinal dysraphism versus what can be observed in healthy age-matched controls; and document changes in those within 1 week after prenatal repair.

MATERIALS AND METHODS: Retrospective evaluation of 349 MR imaging examinations took place, including 274 in controls and 52 in fetuses with open spinal dysraphism, of whom 23 underwent prenatal repair and had additional early postoperative MR images. We evaluated measurements of the brain stem and the posterior fossa and the ventricular width in all populations for their reliability and differences between the groups.

RESULTS: The transverse cerebellar diameter, cerebellar herniation level, clivus-supraocciput angle, transverse diameter of the posterior fossa, posterior fossa area, and ventricular width showed an acceptable intra- and interobserver reliability (intraclass correlation coefficient > 0.5). In fetuses with open spinal dysraphism, these measurements were significantly different from those of healthy fetuses (all with P < .0001). Furthermore, they also changed significantly (P value range = .01 to < .0001) within 1 week after the fetal operation with an evolution toward normal, most evident for the clivus-supraocciput angle (65.9 ± 12.5°; 76.6 ± 10.9; P < .0001) and cerebellar herniation level (-9.9 ± 4.2 mm; -0.7 ± 5.2; P < .0001).

CONCLUSIONS: In fetuses with open spinal dysraphism, brain stem measurements varied substantially between observers. However, measurements characterizing the posterior fossa could be reliably assessed and were significantly different from normal. Following a fetal operation, these deviations from normal values changed significantly within 1 week.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Aertsen M, Verduyckt J, De Keyzer F, et al. Reliability of MR Imaging-Based Posterior Fossa and Brain Stem Measurements in Open Spinal Dysraphism in the Era of Fetal Surgery. AJNR Am J Neuroradiol. 2018. PMID: 30591508. doi:10.3174/ajnr.A5930

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。