文献速递神经介入DSA

高清晰度变焦模式:一种用于神经介入治疗操作的高分辨率X射线显微镜的盲法评估临床效用研究

High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study.
PubMed 文献 · AJNR Am J Neuroradiol · 2018-12-27

本研究在模拟头颅与组织衰减的神经介入体模中,嵌入3D打印颅内血管模型(颈内动脉段动脉瘤),比较194微米像素平板探测器模式与76微米像素互补金属氧化物半导体探测器模式(高清晰度)对血流导向装置释放的显示效果。2名盲法神经介入医师独立评估60对图像,结果高清晰度模式图像被选中的频率至少95%,平均73%被评为「好得多」,且观察者间与观察者内一致性良好。

要点

  • 高清晰度模式(76微米像素)图像比平板探测器(194微米像素)更清晰,视觉上更受偏好。
  • 两名盲法评估者选择高清晰度模式图像的频率均至少95%,平均73%评为「好得多」。
  • 高清晰度模式提供的改善成像可能为神经介入操作带来优势。

核心结论

  • 高清晰度模式图像因分辨率更高而更清晰,视觉上优于平板探测器图像;其改善的成像可能为神经介入操作提供优势。

研究设计与样本

  • 盲法评估临床效用研究,在模拟患者颅骨与组织衰减、嵌入3D打印颅内血管模型(颈内动脉段动脉瘤)的神经介入体模中,分别于平板探测器模式和高清晰度模式下释放血流导向装置,由2名盲法经验丰富的神经介入医师独立评估60对图像。

诊断标准与关键数值

  • 两名评估者均显示良好的观察者间与观察者内一致性,各自选择高清晰度模式图像的频率至少95%。
  • 从总共60对图像中,平均73%的频率将高清晰度图像评为比平板探测器图像「好得多」。

临床应用与阅片要点

  • 高清晰度模式图像更清晰且视觉上更受偏好,可能为神经介入操作提供优势。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Quality of visualization of treatment devices during critical stages of endovascular interventions, can directly impact their safety and efficacy. Our aim was to compare the visualization of neurointerventional procedures and treatment devices using a 194-μm pixel flat panel detector mode and a 76-μm pixel complementary metal oxide semiconductor detector mode (high definition) of a new-generation x-ray detector system using a blinded-rater study.

MATERIALS AND METHODS: Deployment of flow-diversion devices for the treatment of internal carotid artery aneurysms was performed under flat panel detector and high-definition-mode image guidance in a neurointerventional phantom simulating patient cranium and tissue attenuation, embedded with 3D-printed intracranial vascular models, each with an aneurysm in the ICA segment. Image-sequence pairs of device deployments for each detector mode, under similar exposure and FOV conditions, were evaluated by 2 blinded experienced neurointerventionalists who independently selected their preferred image on the basis of visualization of anatomic features, image noise, and treatment device. They rated their selection as either similar, better, much better, or substantially better than the other choice. Inter- and intrarater agreement was calculated and categorized as poor, moderate, and good.

RESULTS: Both raters demonstrating good inter- and intrarater agreement selected high-definition-mode images with a frequency of at least 95% each and, on average, rated the high-definition images as much better than flat panel detector images with a frequency of 73% from a total of 60 image pairs.

CONCLUSIONS: Due to their higher resolution, high-definition-mode images are sharper and visually preferred compared with the flat panel detector images. The improved imaging provided by the high-definition mode can potentially provide an advantage during neurointerventional procedures.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Setlur Nagesh SV, Fennel V, Krebs J, et al. High-Definition Zoom Mode, a High-Resolution X-Ray Microscope for Neurointerventional Treatment Procedures: A Blinded-Rater Clinical-Utility Study. AJNR Am J Neuroradiol. 2018. PMID: 30591511. doi:10.3174/ajnr.A5922

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。