详细胎儿解剖超声检查:2014年共识报告对三级转诊中心的影响

Detailed Fetal Anatomic Ultrasound Examination: Effect of the 2014 Consensus Report on a Tertiary Referral Center.
指南 / 共识 · Ultrasound Q · 2019-01-01

回顾性研究对比2014年美国超声医学研究所共识(76811指南)实施前后,在三级胎儿中心孕18周及以上接受详细超声的624例单胎妊娠(实施前217例,实施后407例)。实施后检查时间增加20%(6.4 vs 7.7分钟,P<0.05),不完整检查增加130%(11% vs 26%,P<0.05),重复检查转诊翻倍(6% vs 13%,P<0.05),但先天性心脏病检出率未改善(3% vs 2%,P=0.3)。

要点

  • 2014年共识新增双腔静脉、主动脉弓、三血管和三血管气管切面后,检查时间增加20%。
  • 不完整检查率从11%升至26%,重复检查转诊率从6%升至13%。
  • 先天性心脏病检出率未改善(3% vs 2%,P=0.3),胎儿超声心动图推荐率无变化(5% vs 6%,P=0.6)。

核心结论

  • 扩展心脏切面导致检查时间延长、不完整检查增多和重复检查增加,但未改变先天性心脏病检出率。

研究设计与样本

  • 回顾性研究,纳入624例单胎妊娠(方案变更前217例,变更后407例),在学术性三级胎儿中心于孕18周及以上行详细超声检查,排除已知畸形胎儿。

关键影像表现/征象

  • 2014年前要求切面:四腔心、左室流出道、右室流出道;2014年后额外要求:双腔静脉、主动脉弓、三血管、三血管气管切面。
  • 所获切面符合美国超声医学研究所/母胎医学会共识。

诊断标准与关键数值

  • 先天性心脏病检出率:方案变更前3% vs 变更后2%(P=0.3),未达统计学显著。
  • 检查时间:方案变更前6.4分钟 vs 变更后7.7分钟,增加20%(P<0.05)。
  • 不完整检查率:方案变更前11% vs 变更后26%,增加130%(P<0.05)。
  • 重复检查转诊率:方案变更前6% vs 变更后13%(P<0.05)。
  • 胎儿超声心动图推荐率:方案变更前5% vs 变更后6%(P=0.6)。

临床应用与阅片要点

  • 扩展心脏切面方案实施后检查时间和不完整检查率增加,阅片和报告需关注切面完成度。
  • 重复检查转诊率随方案变更翻倍,需评估流程影响。
  • 检查完成率与体重指数负相关,提示高体重指数孕妇完成率可能更低。

局限性

  • 本研究为回顾性研究。
  • 本研究在学术性三级胎儿中心进行。
  • 排除已知畸形胎儿。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study evaluates the impact of extended cardiac views on examination time, repeat imaging, and anomaly detection before and after implementation of 76811 guidelines (American Institute of Ultrasound in Medicine Consensus 2014). It is a retrospective study of singleton pregnancies undergoing detailed ultrasound imaging at 18 weeks' gestation or greater before and after the protocol change in an academic, tertiary care fetal center. Views required prior to 2014: 4-chamber, left outflow tract, right outflow tract. Additional views required after 2014: bicaval, aortic arch, 3-vessel, and 3-vessel trachea. Fetuses with known anomalies were excluded. Rates of detection of congenital heart disease (CHD), examination completion, repeat examination recommendation, fetal echocardiogram recommendation, completion by body mass index, and cardiac examination time were determined. Six hundred twenty-four subjects were included, 217 before and 407 after protocol change. Views obtained were as stated in the American Institute of Ultrasound in Medicine/Society for Maternal-Fetal Medicine consensus. Detection of CHD was not improved. Examination times increased by 20% (6.4 vs 7.7 minutes, P < 0.05). Number of incomplete studies increased by 130% (11% to 26%, P < 0.05). Twice as many patients were referred for repeat examination (6% vs 13%, P < 0.05). Completion rates were negatively correlated with body mass index. Recommendations for fetal echocardiogram were unchanged (5% vs 6%, P = 0.6). Additional imaging did not increase detection rate of CHD (3% vs 2%, P = 0.3). Extended cardiac views resulted in increased examination time, more incomplete examinations, and more repeat examinations without changing detection rates of CHD.

来源:Ultrasound Q,查看原文。版权归原作者所有。

引用

  1. Fratto VM, Chang A, Anton T, et al. Detailed Fetal Anatomic Ultrasound Examination: Effect of the 2014 Consensus Report on a Tertiary Referral Center. Ultrasound Q. 2019. PMID: 30516729. doi:10.1097/RUQ.0000000000000392

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。