双能CT尿路造影使用50%减量碘对比剂与单能CT尿路造影使用标准碘剂量的比较
本研究纳入62例泌尿系结石、肿瘤或血尿患者,31例接受50%减量碘剂量的双能CT尿路造影(DECT,50与77 keV重建),与31例性别、年龄、体型匹配的接受标准碘剂量120 kVp单能CT尿路造影(SECT)患者比较。结果显示50 keV DECT在七个测量点的衰减与SECT相同或更高,主观图像质量评分除条纹伪影和尿路轮廓锐利度外与SECT相同或更高。结论认为50%减量碘剂量的DECT尿路造影可能获得与标准剂量SECT尿路造影相同或更高的肾血管及尿路衰减,图像质量测量和评分相似。
要点
- 50 keV DECT在肾动脉、肾静脉及尿路七个测量点的衰减与标准剂量SECT相同或更高。
- DECT主观图像质量评分除条纹伪影和尿路轮廓锐利度外与SECT相同或更高。
- 50%减量碘剂量DECT(平均22 g)与标准剂量SECT(平均44 g)图像质量测量和评分相似。
核心结论
- 50%减量碘剂量的DECT尿路造影可能获得与标准碘剂量120 kVp SECT尿路造影相同或更高的肾血管及尿路衰减,图像质量测量和评分相似。
研究设计与样本
- 研究纳入62例评估泌尿系结石、肿瘤或血尿的患者,31例接受50%减量碘剂量的DECT尿路造影(50和77 keV重建),与31例性别、年龄和体型匹配的接受标准碘剂量120 kVp SECT尿路造影的患者比较;DECT平均碘剂量22 g,SECT平均碘剂量44 g。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to compare dual-energy CT (DECT) urography with a 50% reduced iodine dose to single-energy CT (SECT) urography with a standard iodine dose with respect to attenuation of renal vascular and urinary tract structures and with respect to image quality.
SUBJECTS AND METHODS: The study included 62 patients undergoing evaluation of urinary tract lithiasis, tumor, or hematuria. Thirty-one patients underwent DECT urography with a 50% reduced iodine dose and reconstruction at 50 and 77 keV. These subjects were sex, age, and size matched to a group of 31 patients who underwent 120-kVp SECT urography with a standard iodine dose. The mean iodine dose was 22 g for DECT and 44 g for SECT. Attenuation was measured at seven locations in the renal arteries, renal veins, and urinary tract. Two reviewers subjectively scored the image quality parameters image noise, sharpness of urinary tract contours, enhancement of urinary structures, and streak artifacts.
RESULTS: Mean DECT attenuation at 50 keV was the same as or greater than SECT attenuation at each of the seven locations. Measured image noise was highest at 50-keV DECT but was the same for 77-keV DECT and 120-kVp SECT. Mean subjective scores for DECT image quality parameters were the same as or higher than those of SECT, except for streak artifact and sharpness of urinary tract contours.
CONCLUSION: DECT urography with a 50% reduced iodine dose may result in measured renal vascular and urinary tract attenuation the same as or higher than and image quality measurements and scores similar to those obtained with 120-kVp SECT urography with a standard iodine dose.
引用
- Shuman WP, Mileto A, Busey JM, et al. Dual-Energy CT Urography With 50% Reduced Iodine Dose Versus Single-Energy CT Urography With Standard Iodine Dose. AJR Am J Roentgenol. 2018. PMID: 30422713. doi:10.2214/AJR.18.19720
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。