文献速递泌尿生殖腹部CT

低管电压CT尿路造影联合低浓度碘对比剂与迭代重建:与传统CT尿路造影比较的多机构随机对照试验

Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography.
PubMed 文献 · Korean J Radiol · 2018-10-18

本研究为16家医院前瞻性随机对照试验,299例患者随机分为低管电压低碘浓度联合迭代重建组(150例)与传统CT尿路造影组(149例)。低管电压组有效辐射剂量显著更低(5.73±4.04 vs 8.43±4.38 mSv),诊断可接受性不劣于传统组,尿路各段平均衰减值、信噪比、对比噪声比及品质因数均显著更高。结论认为低管电压联合迭代重建的诊断可接受性和定量图像质量不劣于传统CTU,且辐射剂量与总碘负荷均降低。

要点

  • 低管电压低碘浓度联合迭代重建CTU的有效辐射剂量为5.73±4.04 mSv,显著低于传统CTU的8.43±4.38 mSv。
  • 低管电压组诊断可接受性至少达到标准水平(评分≥3分),且不劣于传统CTU。
  • 低管电压组尿路各预设节段的平均衰减值、信噪比、对比噪声比及品质因数均显著高于传统CTU组。

核心结论

  • 低管电压低碘浓度联合迭代重建CTU的诊断可接受性与定量图像质量不劣于传统CTU,且辐射剂量与总碘负荷均降低。

研究设计与样本

  • 前瞻性、多机构、随机对照试验,在16家医院使用不同厂商的CT扫描仪进行。
  • 共纳入299例患者,随机分为低管电压低碘浓度联合迭代重建CTU组(150例,80 kVp、240 mgI/mL)和传统CTU组(149例,120 kVp、350 mgI/mL,滤波反投影重建)。
  • 评估指标包括整体诊断可接受性、锐利度和噪声,以及尿路平均衰减值、信噪比、对比噪声比和品质因数。

诊断标准与关键数值

  • 低管电压组诊断可接受性至少达到标准水平(评分≥3分),且不劣于传统CTU。
  • 低管电压组有效辐射剂量为5.73±4.04 mSv,传统CTU组为8.43±4.38 mSv。
  • 低管电压组尿路所有预设节段的平均衰减值、平均信噪比、对比噪声比及品质因数均显著高于传统CTU组。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU.

MATERIALS AND METHODS: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated.

RESULTS: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group.

CONCLUSION: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Kim SY, Cho JY, Lee J, et al. Low-Tube-Voltage CT Urography Using Low-Concentration-Iodine Contrast Media and Iterative Reconstruction: A Multi-Institutional Randomized Controlled Trial for Comparison with Conventional CT Urography. Korean J Radiol. 2018. PMID: 30386143. doi:10.3348/kjr.2018.19.6.1119

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。