文献速递心血管儿科影像CT

稀释对比剂在婴儿心血管CT血管成像测试扫描中的效用

Usefulness of diluted contrast medium for test-scanning of infants scheduled for contrast-enhanced cardiovascular computed tomography angiography.
PubMed 文献 · Br J Radiol · 2018-11-14

研究将120例连续婴儿均分为两组,比较未稀释与稀释对比剂测试扫描预测心血管CT血管成像对比增强的能力。稀释对比剂方案所有测试扫描均见峰值增强,与肺动脉和升主动脉增强呈强正相关(r=0.61和r=0.63,p<0.01),作者认为稀释对比剂测试扫描有助于预测婴儿先心病CCTA的对比增强。

要点

  • 稀释对比剂测试扫描可显示最佳对比增强峰值时间。
  • 稀释方案与肺动脉及升主动脉增强呈强正相关(r=0.61和0.63,p<0.01)。
  • 未稀释方案约10%测试扫描未显示峰值增强。

核心结论

  • 稀释对比剂测试扫描可揭示最佳对比增强峰值时间,并有助于预测婴儿先天性心脏病CCTA中肺动脉和升主动脉的对比增强。

研究设计与样本

  • 将120例连续接受64排MDCT心血管CT血管成像的婴儿等分为两组:P1组测试团注为未稀释对比剂(注射量=总体重×1.2 ml,注射时间5 s),P2组为总体重×4.0 ml(对比剂15%、生理盐水85%,注射时间16 s)。

关键影像表现/征象

  • P2组所有测试扫描均观察到峰值对比增强。
  • P1组约10%测试扫描未显示峰值对比增强。

诊断标准与关键数值

  • 测试扫描对比增强采用3分视觉量表记录。
  • P2组肺动脉对比增强相关系数r=0.61(p<0.01),升主动脉r=0.63(p<0.01)。
  • P1组肺动脉对比增强相关系数r=0.26(p<0.01),升主动脉r=0.33(p<0.01)。

临床应用与阅片要点

  • 作者认为稀释对比剂测试扫描有助于通过基于对比噪声的扫描为婴儿CCTA研究选择最佳扫描参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE:: To compare the ability of test scans with undiluted and diluted contrast medium (CM) to predict contrast enhancement (CE) on cardiovascular CT angiography (CCTA) images of infants.

METHODS:: We divided 120 consecutive infants who had undergone CCTA on a 64-MDCT scanner into two equal groups. In one group, the test bolus consisted of undiluted CM [protocol 1 (P1): injection volume = total body weight × 1.2 ml, injection time 5 s], in the other (P2) it was total body weight × 4.0 ml (CM 15%, saline 85%, injection time 16 s). CE on the test scans was recorded on a 3-point visual scale. We investigated the relation for CE in the pulmonary artery and ascending aorta between the P1 or P2 test scans and CCTA images.

RESULTS:: While peak CE was observed on all test scans performed with P2, in approximately 10 % of test scans obtained under P1, peak CE was not visualized. There was a strong positive linear correlation for CE of the pulmonary artery and ascending aorta on P2 images (r = 0.61 and r = 0.63, p < 0.01); under P1 the correlation was weak (r = 0.26 and r = 0.33, p < 0.01).

CONCLUSION:: Test-scanning with diluted CM revealed the optimal CE peak time and was useful for predicting CE on CCTA scans of the pulmonary artery and ascending aorta in infants with congenital heart disease.

ADVANCES IN KNOWLEDGE:: Diluted test scans help to select the optimal scan parameters for the CCTA study of infants by using contrast-to-noise-based scanning.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Masuda T, Funama Y, Nakaura T, et al. Usefulness of diluted contrast medium for test-scanning of infants scheduled for contrast-enhanced cardiovascular computed tomography angiography. Br J Radiol. 2018. PMID: 30412445. doi:10.1259/bjr.20180572

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。