应用超声生物显微镜无创在体评估大鼠颈动脉球囊损伤模型再内皮化过程
本研究分析3个实验、3种品系大鼠(Sprague Dawley、Wistar、糖尿病Goto-Kakizaki)颈动脉球囊损伤后2周和4周的超声生物显微镜(30-70 MHz)数据,以内膜增生厚度作为再内皮化的替代测量。UBM与伊文思蓝整体染色法测量再内皮化长度总体显著相关(Spearman r=0.63;P<.0001),Bland-Altman检验显示两者一致,免疫组化证实UBM检测的再内皮化区域存在内皮。结论:UBM可用于大鼠颈动脉球囊损伤后重复在体评估再内皮化。
要点
- UBM(30-70 MHz)可重复在体测量大鼠颈动脉球囊损伤后内膜增生厚度,作为再内皮化的替代指标。
- UBM与伊文思蓝整体染色测量再内皮化长度总体显著相关(Spearman r=0.63;P<.0001),Bland-Altman显示两者一致。
- 免疫组化证实UBM判定的再内皮化区域存在内皮,支持该无创评估方法的可靠性。
核心结论
- 超声生物显微镜可用于大鼠颈动脉球囊损伤后重复在体评估再内皮化过程。
研究设计与样本
- 研究论文;分析3个不同实验、3种大鼠品系(Sprague Dawley、Wistar、糖尿病Goto-Kakizaki)的超声生物显微镜数据;所有动物行颈动脉球囊损伤,于损伤后2周和4周以UBM(30-70 MHz)检查;处死(损伤后4周)时行伊文思蓝整体染色,随后取材行组织化学和免疫组化评估。
关键影像表现/征象
- UBM将再内皮化定义为从颈动脉分叉至内膜增生最远端可见边缘的长度。
诊断标准与关键数值
- UBM与伊文思蓝整体染色所有再内皮化测量值比较:Spearman r=0.63;P<.0001。
- Sprague Dawley大鼠:Spearman r=0.70;P<.0001。
- Wistar大鼠:Spearman r=0.36;P<.081。
- Goto-Kakizaki大鼠:Spearman r=0.70;P<.05。
- Bland-Altman检验显示伊文思蓝整体染色与UBM之间一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Ultrasound biomicroscopy (UBM), or ultra high-frequency ultrasound, is a technique used to assess the anatomy of small research animals. In this study, UBM was used to assess differences in intimal hyperplasia thickness as a surrogate measurement of the re-endothelialization process after carotid artery balloon injury in rats.
METHODS: Ultrasound biomicroscopic data from 3 different experiments and rat strains (Sprague Dawley, Wistar, and diabetic Goto-Kakizaki) were analyzed. All animals were subjected to carotid artery balloon injury and examined with UBM (30-70 MHz) 2 and 4 weeks after injury. Re-endothelialization on UBM was defined as the length from the carotid bifurcation to the most distal visible edge of the intimal hyperplasia. En face staining with Evans blue dye was performed at euthanasia 4 weeks after injury, followed by tissue harvesting for histochemical and immunohistochemical evaluations.
RESULTS: A significant correlation (Spearman r = 0.63; P < .0001) was identified when comparing all measurements of re-endothelialization obtained from UBM and en face staining. The findings revealed a similar pattern for all rat strains: Sprague Dawley (Spearman r = 0.70; P < .0001), Wistar (Spearman r = 0.36; P < .081), and Goto-Kakizaki (Spearman r = 0.70; P < .05). A Bland-Altman test showed agreement between en face staining and UBM. Immunohistochemical staining confirmed the presence of the endothelium in the areas detected as re-endothelialized by the UBM assessment.
CONCLUSIONS: Ultrasound biomicroscopy can be used for repeated in vivo assessment of re-endothelialization after carotid artery balloon injury in rats.
引用
- Röhl S, Eriksson L, Saxelin R, et al. Noninvasive in vivo Assessment of the Re-endothelialization Process Using Ultrasound Biomicroscopy in the Rat Carotid Artery Balloon Injury Model. J Ultrasound Med. 2018. PMID: 30426541. doi:10.1002/jum.14858
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。