文献速递外周血管泌尿生殖MRDSA

无对比剂静态间隔单次激发磁共振血管成像与有创二氧化碳血管成像在外周动脉疾病合并慢性肾功能不全患者中的多观察者比较研究

Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency.
PubMed 文献 · Eur J Radiol · 2018-09-28

本研究回顾性纳入16例外周动脉疾病合并重度肾功能不全(eGFR<30 ml/min/1.73 m²)患者,比较3 T QISS-MRA与二氧化碳血管成像的图像质量及诊断效能,以经验丰富介入放射科医生的CO2血管成像为标准参考。QISS-MRA检测≥50%狭窄的敏感度91.5%、特异度94.2%、阳性预测值86.0%、阴性预测值96.6%,ICC为0.88,图像质量主观评分中位值在骨盆、大腿、小腿分别为4、5、5,整体优于CO2血管成像。

要点

  • QISS-MRA在骨盆、大腿、小腿的动脉信号强度中位评分分别为4、5、5,静脉重叠分别为4、5、5。
  • 以CO2血管成像为标准,QISS-MRA检测≥50%狭窄的敏感度91.5%、特异度94.2%、阳性预测值86.0%、阴性预测值96.6%。
  • CO2血管成像的动脉充盈主观评分在骨盆、大腿、小腿分别为3、4、3,ICC为0.63。

核心结论

  • QISS-MRA的图像质量优于有创CO2血管成像,且对PAD的检测和排除具有高诊断效能。

研究设计与样本

  • 回顾性研究,连续纳入16例PAD合并重度肾功能不全(eGFR<30 ml/min/1.73 m²)患者,均在90天内接受3 T QISS-MRA和CO2导管血管成像,以经验丰富介入放射科医生的CO2血管成像为标准参考方法,由4名不同经验水平的独立读者随机顺序评估。

关键影像表现/征象

  • QISS-MRA定性参数中位值:动脉信号强度骨盆4、大腿5、小腿5;静脉重叠骨盆4、大腿5、小腿5;磁敏感伪影骨盆5、大腿5、小腿5;运动伪影骨盆4、大腿5、小腿5;心电图相关伪影骨盆5、大腿5、小腿5。CO2血管成像动脉充盈评分骨盆3、大腿4、小腿3。

诊断标准与关键数值

  • 共167个节段可用于直接比较,≥50%狭窄的患病率为28.1%;QISS-MRA检测≥50%狭窄的敏感度91.5%、特异度94.2%、阳性预测值86.0%、阴性预测值96.6%,ICC为0.88;图像质量ICC分别为0.74、0.73、0.93、0.69、0.79;CO2血管成像动脉充盈ICC为0.63。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Non-contrast-enhanced quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) and invasive carbon dioxide (CO2) angiography are suggested as nephroprotective methods for accurate staging of peripheral arterial disease (PAD) in patients with chronic renal insufficiency (CRI). The aim of our study was to compare the image quality of both examinations.

METHODS: 16 consecutive PAD patients with highly impaired renal function (estimated glomerular filtration rate (eGFR) < 30 ml/min/1.73 m²) who underwent 3 T MRA with QISS and catheter angiography with CO2 within 90 days were retrospectively included. Subjective image quality was determined using a five-point Likert scale (1, non-diagnostic; 5, excellent) and presence of significant (≥50%) stenoses of pelvic and lower extremity arteries (21-segment-model) was evaluated per-region and per-segment, respectively, in random order by four independent readers with different levels of experience. CO2 angiography of an experienced interventional radiologist was considered the standard reference method.

RESULTS: 167 segments were available for direct comparison with a prevalence of ≥50% stenoses of 28.1%. QISS-MRA yield was: sensitivity 91.5%, specificity 94.2%, positive predictive value 86.0% and negative predictive value 96.6%, with an intraclass correlation coeffcient (ICC) of 0.88. Median values of qualitative imaging parameters for QISS-MRA were as follows: arterial signal intensity: 4 (pelvis), 5 (thigh), 5 (calf); venous overlay: 4, 5, 5; susceptibility artifacts: 5, 5, 5; motion artifacts: 4, 5, 5; ECG-related artifacts: 5, 5, 5. ICC-values for image quality were 0.74, 0.73, 0.93, 0.69 and 0.79, respectively. Arterial opacification at CO2 angiography was rated 3, 4, 3, with an ICC of 0.63.

CONCLUSIONS: Image quality of non-invasive unenhanced MR angiography with QISS was preferred over invasive CO2 angiography, whilst taking into account that it offers high diagnostic performance for the detection and ruling out of PAD.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Arendt CT, Leithner D, Lenga L, et al. Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency. Eur J Radiol. 2018. PMID: 30396647. doi:10.1016/j.ejrad.2018.09.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。