定量评估T2*弛豫时间用于鉴别急性良性与恶性椎体骨折
这项前瞻性研究纳入37例患者共52个椎体压缩性骨折,以骨活检病理为参考标准,评估3.0T MRI六回波改良Dixon梯度回波序列测量的椎体内T2*及T2*比值对急性良恶性骨折的鉴别效能。恶性骨折T2*和T2*比值均显著高于良性骨折,T2*比值AUC为0.88、准确率89%,T2*的AUC为0.77、准确率73%。
要点
- 恶性椎体压缩骨折的T2*比值(骨折椎/正常椎)为2.9±1.6,急性良性骨折为1.2±0.7。
- T2*比值鉴别良恶性骨折的AUC为0.88、准确率89%,优于T2*的AUC 0.77、准确率73%。
- 椎体T2*短期重复性测量的均方根绝对精度误差为0.44 ms。
核心结论
- 定量评估椎体骨髓T2*弛豫时间对鉴别急性良性与恶性椎体压缩骨折具有良好诊断准确率。
研究设计与样本
- 前瞻性研究,连续纳入37例患者共52个椎体压缩骨折,以直接骨活检和组织病理学确认作为良恶性分类参考标准;所有患者除常规临床脊柱MRI(至少包括矢状位T1加权、T2加权和T2 SPAIR加权序列)外,均加扫3.0T矢状位六回波改良Dixon梯度回波序列;另对5名健康受试者扫描三次以确定椎体T2*测量的短期重复性。
关键影像表现/征象
- 恶性椎体压缩骨折的T2*为30±11 ms,急性良性骨折为19±11 ms(p=0.001)。
- 恶性椎体压缩骨折的T2*比值为2.9±1.6,急性良性骨折为1.2±0.7(p<0.001)。
诊断标准与关键数值
- T2*鉴别急性良性与恶性椎体压缩骨折的AUC为0.77,准确率73%。
- T2*比值鉴别急性良性与恶性椎体压缩骨折的AUC为0.88,准确率89%。
- 椎体T2*短期重复性的均方根绝对精度误差为0.44 ms。
临床应用与阅片要点
- 在常规脊柱MRI基础上加扫3.0T矢状位六回波改良Dixon梯度回波序列,可行椎体骨髓T2*及T2*比值的定量测量。
- 采用感兴趣区分析计算骨折椎T2*与正常椎T2*的比值,T2*比值对鉴别急性良恶性椎体压缩骨折的准确率高于T2*。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this prospective study was to evaluate the diagnostic performance of T2*-weighted magnetic resonance imaging (MRI) to differentiate between acute benign and neoplastic vertebral compression fractures (VCFs).
MATERIALS AND METHODS: Thirty-seven consecutive patients with a total of 52 VCFs were prospectively enrolled in this IRB approved study. All VCFs were categorized as either benign or malignant according to direct bone biopsy and histopathologic confirmation. In addition to routine clinical spine MRI including at least sagittal T1-weighted, T2-weighted and T2 spectral attenuated inversion recovery (SPAIR)-weighted sequences, all patients underwent an additional sagittal six-echo modified Dixon gradient-echo sequence of the spine at 3.0-T. Intravertebral T2* and T2*ratio (fracture T2*/normal vertebrae T2*) for acute benign and malignant VCFs were calculated using region-of-interest analysis and compared between both groups. Additional receiver operating characteristic analyses were performed. Five healthy subjects were scanned three times to determine the short-term reproducibility of vertebral T2* measurements.
RESULTS: There were 27 acute benign and 25 malignant VCFs. Both T2* and T2*ratio of malignant VCFs were significantly higher compared to acute benign VCFs (T2*, 30 ± 11 vs. 19 ± 11 ms [p = 0.001]; T2*ratio, 2.9 ± 1.6 vs. 1.2 ± 0.7 [p < 0.001]). The areas under the curve were 0.77 for T2* and 0.88 for T2*ratio, yielding an accuracy of 73% and 89% for distinguishing acute benign from malignant VCFs. The root mean square absolute precision error was 0.44 ms as a measure for the T2* short-term reproducibility.
CONCLUSION: Quantitative assessment of vertebral bone marrow T2* relaxation times provides good diagnostic accuracy for the differentiation of acute benign and malignant VCFs.
引用
- Schmeel FC, Luetkens JA, Feißt A, et al. Quantitative evaluation of T2* relaxation times for the differentiation of acute benign and malignant vertebral body fractures. Eur J Radiol. 2018. PMID: 30396672. doi:10.1016/j.ejrad.2018.09.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。