文献速递骨肌MR

三维MRI诊断膝关节半月板损伤:诊断性能的系统评价与Meta分析

Diagnosis of Knee Meniscal Injuries by Using Three-dimensional MRI: A Systematic Review and Meta-Analysis of Diagnostic Performance.
PubMed 文献 · Radiology · 2018-11-20

该系统评价与Meta分析纳入1985至2017年发表的31项研究(共1743例三维膝关节MRI检查,其中23项同时报告二维MRI结果),以手术为参考标准,比较三维与二维MRI诊断膝关节半月板损伤的性能。三维快速自旋回波与三维梯度回波序列的诊断性能与二维序列相当,三维快速自旋回波对半月板外侧损伤的敏感度略优于三维梯度回波。

要点

  • 三维快速自旋回波与三维梯度回波序列诊断膝关节半月板损伤的性能与二维序列相当。
  • 三维快速自旋回波对半月板外侧损伤的敏感度略优于三维梯度回波(84.6% vs 75%,P = .01)。
  • 三维序列行多平面重组后特异度提高(P = .02)。

核心结论

  • 三维快速自旋回波与三维梯度回波序列诊断膝关节半月板损伤的性能与二维序列相当,三维快速自旋回波对半月板外侧损伤的敏感度略优于三维梯度回波。

研究设计与样本

  • 系统评价与Meta分析,检索1985至2017年发表的原始研究,纳入31项研究(1743例三维膝关节MRI检查,其中23项同时报告二维MRI结果),以手术为参考标准。

诊断标准与关键数值

  • 三维快速自旋回波与二维MRI比较:汇总敏感度90.0%(P = .2)对88.5%,汇总特异度91%(P = .3)对90.1%。
  • 三维梯度回波与二维MRI比较:汇总敏感度90.1%(P = .2)对88.5%,汇总特异度89.8%(P = .7)对90.1%。
  • 半月板外侧损伤敏感度:三维快速自旋回波84.6% vs 三维梯度回波75%(P = .01)。
  • 三维序列行多平面重组后特异度提高(P = .02)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the diagnostic performance of three-dimensional (3D) MRI for depicting meniscal injuries of the knee by using surgery as the standard of reference. Materials and Methods A literature search was performed to identify original studies published between 1985 and 2017. Summary receiver operating characteristic curve and sensitivity analyses were performed to compare the diagnostic performance of 3D versus two-dimensional (2D) MRI for the assessment of knee meniscal injuries and to evaluate the impact of relevant covariates on the diagnostic performance for assessment of knee meniscal injuries. Results Of identified records, 31 studies (1743 3D knee MRI examinations) were included (23 studies also reported the results of 2D MRI). All studies before 2008 used gradient-echo (GRE) sequences, whereas all studies after 2011 used fast spin-echo (FSE) sequences. By comparing FSE and GRE sequences with 2D MRI, pooled estimate of sensitivity (90.0%; P = .2 and 90.1%; P = .2 vs 88.5%) and pooled estimate of specificity (91%; P = .3 and 89.8% vs 90.1%; P = .7) were comparable. The 3D FSE sequences demonstrated similar diagnostic performance as 3D GRE sequences, except for slightly improved sensitivity for depicting lateral meniscal injuries (FSE, 84.6%; GRE, 75%; P = .01). The specificity of 3D sequences improved when multiplanar reformatting was performed (P = .02). Conclusion Both three-dimensional (3D) fast spin-echo (FSE) and 3D gradient-echo (GRE) sequences had similar diagnostic performance as two-dimensional sequences, with slight superior sensitivity of 3D FSE sequences compared with 3D GRE sequences for depicting lateral meniscal injuries of the knee. © RSNA, 2018 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Shakoor D, Kijowski R, Guermazi A, et al. Diagnosis of Knee Meniscal Injuries by Using Three-dimensional MRI: A Systematic Review and Meta-Analysis of Diagnostic Performance. Radiology. 2018. PMID: 30457479. doi:10.1148/radiol.2018181212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。