文献速递骨肌MR

采用导航径向成像自旋回波扩散(RAISED)序列的关节软骨扩散张量成像

Diffusion tensor imaging of articular cartilage using a navigated radial imaging spin-echo diffusion (RAISED) sequence.
PubMed 文献 · Eur Radiol · 2018-10-31

在3T上验证RAISED序列用于关节软骨高分辨率扩散张量成像,使用非线性运动校正算法,在体模中测试涡流稳健性,并在无症状者(n=6)、可疑KL 1(n=9)和轻度KL 2(n=9)膝骨关节炎受试者中采集DTI。运动校正后MD和FA的组间差异才显著,RAISED序列在体模和活体评估中可重复性好,可能有助于区分健康与OA受试者。

要点

  • RAISED序列在3T下可行,使用非线性运动校正后MD和FA的组间差异才显著。
  • MD在KL 1受试者双侧股骨髁(7-9%)和KL 2受试者内侧(11-17%)及外侧(10-12%)间室显著升高。
  • FA在KL 1受试者内侧股骨髁(-11%)和KL 2受试者所有三个间室(-18至-11%)显著降低。

核心结论

  • RAISED序列结合所提出的重建框架可在3T下可重复地评估活体DTI参数,并可能在大感兴趣区内检测疾病的早期阶段。

研究设计与样本

  • 方法学验证研究,包括体模测试、温度依赖性自由水扩散测量、运动校正验证(与单次激发扩散加权平面回波成像比较),以及在无症状受试者(n=6)、可疑KL 1(n=9)和轻度KL 2(n=9)症状性膝骨关节炎受试者中采集DTI,并在3名无症状和3名OA受试者中进行重测评估;未报告中心数。

诊断标准与关键数值

  • 全局重测重复性的均方根变异系数:MD为3.54%,FA为5.34%。
  • MD在KL 1受试者双侧股骨髁升高7-9%,在KL 2受试者内侧间室升高11-17%、外侧间室升高10-12%。
  • FA在KL 1受试者内侧股骨髁降低11%,在KL 2受试者所有三个间室降低18%至11%。
  • MD和FA的组间差异仅在运动校正后显著。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To validate a radial imaging spin-echo diffusion tensor (RAISED) sequence for high-resolution diffusion tensor imaging (DTI) of articular cartilage at 3 T.

METHODS: The RAISED sequence implementation is described, including the used non-linear motion correction algorithm. The robustness to eddy currents was tested on phantoms, and accuracy of measurement was assessed with measurements of temperature-dependent diffusion of free water. Motion correction was validated by comparing RAISED with single-shot diffusion-weighted echo-planar imaging (EPI) measures. DTI was acquired in asymptomatic subjects (n = 6) and subjects with doubtful (Kellgren-Lawrence [KL] grade 1, n = 9) and mild (KL = 2, n = 9) symptomatic knee osteoarthritis (OA). MD and FA values without correction, and after all corrections, were calculated. A test-retest evaluation of the DTI acquisition on three asymptomatic and three OA subjects was also performed.

RESULTS: The root mean squared coefficient of variation of the global test-restest reproducibility was 3.54% for MD and 5.34% for FA. MD was significantly increased in both femoral condyles (7-9%) of KL 1 and in the medial (11-17%) and lateral (10-12%) compartments of KL 2 subjects. Averaged FA presented a trend of lower values with increasing KL grade, which was significant for the medial femoral condyle (-11%) of KL 1 and all three compartments in KL 2 subjects (-18 to -11%). Group differences in MD and FA were only significant after motion correction.

CONCLUSION: The RAISED sequence with the proposed reconstruction framework provides reproducible assessment of DTI parameters in vivo at 3 T and potentially the early stages of the disease in large regions of interest.

KEY POINTS: • DTI of articular cartilage is feasible at 3T with a multi-shot RAISED sequence with non-linear motion correction. • RAISED sequence allows estimation of the diffusion indices MD and FA with test-retest errors below 4% (MD) and 6% (FA). • RAISED-based measurement of DTI of articular cartilage with non-linear motion correction holds potential to differentiate healthy from OA subjects.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Duarte A, Ruiz A, Ferizi U, et al. Diffusion tensor imaging of articular cartilage using a navigated radial imaging spin-echo diffusion (RAISED) sequence. Eur Radiol. 2018. PMID: 30382348. doi:10.1007/s00330-018-5780-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。