文献速递甲状腺与浅表头颈US

Kwak TIRADS 用于甲状腺不确定结节诊断评估的系统评价与 Meta 分析

A systematic review and meta-analysis of the Kwak TIRADS for the diagnostic assessment of indeterminate thyroid nodules.
PubMed 文献 · Clin Radiol · 2018-10-25

该系统评价与 Meta 分析检索多个数据库,纳入 6 篇文献、共 1,096 个甲状腺不确定结节,评估 Kwak TIRADS 的诊断效能。合并敏感度 0.913、特异度 0.347、LR+ 1.396、LR- 0.341、DOR 5.832、SROC 曲线下面积 0.7180。作者结论认为,以 3/4a 为 cut-off 时敏感度高但特异度低,采用更高的 Kwak TIRADS cut-off 可能有助于排除更多良性病灶并降低不必要手术率。

要点

  • Kwak TIRADS 以 3/4a 为 cut-off 评估不确定结节时合并敏感度 0.913、特异度 0.347。
  • 合并 LR+ 1.396、LR- 0.341、DOR 5.832、SROC 曲线下面积 0.7180。
  • 作者认为以 3/4a 为 cut-off 敏感度高但特异度低,排除良性病灶能力有限。

核心结论

  • Kwak TIRADS 以 3/4a 为 cut-off 评估不确定病灶时敏感度高但特异度低,不足以排除良性病灶。
  • 作者认为采用更高的 Kwak TIRADS cut-off 可能有助于排除更多良性病灶并降低不必要手术率。

研究设计与样本

  • 系统评价与 Meta 分析,检索 PubMed、Cochrane database、ScienceDirect 和 EMBASE 数据库的相关文献。
  • 共纳入 6 篇文献,描述 1,096 个结节,计算合并敏感度、特异度、LR+、LR-、DOR 及 SROC 曲线下面积。

诊断标准与关键数值

  • Kwak TIRADS 以 3/4a 为 cut-off 评估不确定结节:合并敏感度 0.913、特异度 0.347。
  • 合并 LR+ 1.396、LR- 0.341、DOR 5.832。
  • SROC 曲线下面积(AUC)为 0.7180。

临床应用与阅片要点

  • 作者认为以 3/4a 为 cut-off 时敏感度高但特异度低,用于排除良性病灶的价值有限。
  • 作者认为采用更高的 Kwak TIRADS cut-off 可能有助于排除更多良性病灶并降低不必要手术率。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To explore the diagnostic usefulness of the Thyroid Imaging Reporting and Data System (TIRADS) classification proposed by Kwak in indeterminate nodules using a systematic literature review.

MATERIAL AND METHODS: The PubMed, Cochrane database, ScienceDirect, and EMBASE databases were searched for relevant articles. A meta-analysis was performed to calculate pooled sensitivity, specificity, negative and positive likelihood ratios (LR- and LR+), diagnostic odds ratio (DOR), and area under the curve (AUC) from summarised receiver operating characteristic (SROC) curves.

RESULTS: Six publications describing 1,096 nodules were analysed. Overall pooled sensitivity, specificity, LR+, LR-, DOR, and AUC for SROC were 0.913, 0.347, 1.396, 0.341, 5.832, and 0.7180, respectively.

CONCLUSIONS: Kwak TIRADS classification with 3/4a cut-off for indeterminate lesions has high sensitivity but low specificity to exclude benign lesions. A higher Kwak TIRADS cut-off could help exclude larger numbers of benign lesions and lower the rate of unnecessary surgeries.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Migda B, Migda M, Migda MS, et al. A systematic review and meta-analysis of the Kwak TIRADS for the diagnostic assessment of indeterminate thyroid nodules. Clin Radiol. 2018. PMID: 30482561. doi:10.1016/j.crad.2018.09.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。