研究由两名放射科医师回顾62例儿童74个经组织病理证实的甲状腺结节的超声图像,评估ACR TI-RADS的诊断效能。54个良性、20个恶性,恶性结节中95.0%为TI-RADS 4或5类;观察者内一致性κ=0.69-0.77,观察者间κ=0.37;AUC为0.75,TI-RADS 5类结节恶性风险为1-4类的10.44倍。

要点

  • 儿童甲状腺结节中,20个恶性结节有19个(95.0%)被评为ACR TI-RADS 4或5类。
  • ACR TI-RADS类别每增加1级,恶性似然比增加2.63倍(95%CI 1.08-6.41;P=0.03)。
  • TI-RADS 5类结节恶性风险为1-4类结节的10.44倍(95%CI 2.71-40.21;P<0.0001)。

核心结论

  • ACR TI-RADS在儿童人群中能较好区分良恶性甲状腺结节,尤其在TI-RADS 5类时。

研究设计与样本

  • 回顾性评估62例儿童74个经组织病理证实的甲状腺结节的超声图像,由两名放射科医师独立评分并确定ACR TI-RADS类别(1-5类),计算观察者内和观察者间Kappa系数,采用广义线性混合效应模型估计恶性比值比并构建补充ROC曲线。

诊断标准与关键数值

  • 74个结节中54个良性、20个恶性,中位ACR TI-RADS类别为4类(四分位距4-5);20个恶性结节中19个(95.0%)为TI-RADS 4或5类;观察者内一致性κ=0.69-0.77(P<0.001),观察者间一致性κ=0.37(P=0.002);单变量分析TI-RADS类别每增加1级恶性似然比增加2.63倍(95%CI 1.08-6.41;P=0.03);调整结节大小后调整OR=2.27(95%CI 0.93-5.54;P=0.07);AUC=0.75(95%CI 0.64-0.86);最佳截断点为TI-RADS 5类,5类结节恶性风险为1-4类的10.44倍(95%CI 2.71-40.21;P<0.0001)。

临床应用与阅片要点

  • 在儿童甲状腺结节超声评估中可采用ACR TI-RADS进行恶性风险分层,TI-RADS 5类提示恶性风险较高。

局限性

  • 调整结节大小后,TI-RADS类别与恶性的关联仅为边缘性(调整OR=2.27;95%CI 0.93-5.54;P=0.07)。
  • 观察者间一致性为中等(κ=0.37;P=0.002)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to assess the diagnostic performance of the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TIRADS) for malignancy risk in pediatric thyroid nodules.

MATERIALS AND METHODS: Two radiologists reviewed ultrasound images of 74 tissue-proven thyroid nodules in 62 children. Points were given for individual features and then added to determine the ACR TI-RADS category, ranging from 1 (benign) to 5 (high suspicion). Kappa coefficients were generated to assess intra- and interobserver agreement. Generalized linear mixed-effects models were used to estimate the odds of malignancy with construction of a supplementary ROC curve.

RESULTS: Fifty-four nodules were benign and 20 were malignant, with a median ACR TI-RADS category of 4 (interquartile range, 4-5). Nineteen of 20 (95.0%) malignant nodules were rated as TI-RADS category 4 or 5. There was substantial intraobserver agreement (κ = 0.69-0.77; p < 0.001) and moderate interobserver agreement (κ = 0.37; p = 0.002) for TIRADS category. Univariable analysis showed that, with every 1-unit increase of TI-RADS category, the likelihood of malignancy increased 2.63 times (95% CI, 1.08-6.41; p = 0.03). After adjusting for nodule size, TI-RADS category remained marginally associated with malignancy (adjusted odds ratio, 2.27; 95% CI, 0.93-5.54; p = 0.07). The AUC was 0.75 (95% CI, 0.64-0.86). An optimal cut point of TI-RADS category 5 was selected, with TI-RADS category 5 nodules 10.44 times (95% CI, 2.71-40.21; p < 0.0001) more likely than categories 1-4 nodules to be malignant.

CONCLUSION: ACR TI-RADS discriminates well between malignant and benign nodules in a pediatric population, particularly at TI-RADS category 5.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Lim-Dunham JE, Toslak IE, Reiter MP, et al. Assessment of the American College of Radiology Thyroid Imaging Reporting and Data System for Thyroid Nodule Malignancy Risk Stratification in a Pediatric Population. AJR Am J Roentgenol. 2018. PMID: 30403525. doi:10.2214/AJR.18.20099

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。